o Power does not turn on/Power is turned off
Symptom
Power does not turn on.
0
0
Power automatically turns
0
off.
Power turns off and the
0
protection circuit indicator
flashes in red approx.
0
every 2 seconds.
Power turns off and the
0
protection circuit indicator
flashes in red approx.
every 0.5 seconds.
0
0
Front panel
Display
Playback
Check whether the power cord is correctly inserted into the power outlet.
This unit is in the standby mode. Press the power button (AMP POWER X).
The auto standby mode is on. When approx. 30 minutes pass with no audio input, this unit automatically
enters the standby mode. To turn Auto Standby mode off, set "Auto Standby" on the setup menu to "Off".
The protection circuit has been activated due to a rise in temperature within this unit. Turn the power off,
wait about an hour until this unit cools down sufficiently, and then turn the power on again.
Please re-install this unit in a place having good ventilation.
Check the speaker connections. The protection circuit may have been activated because speaker cable
core wires came in contact with each other or a core wire was disconnected from the connector and
came in contact with the rear panel of this unit. After unplugging the power cord, firmly re-twist the core
wire, and then reconnect the wire.
Turn down the volume and turn on the power again.
This unit's amplifier circuit has failed. Unplug the power cord and contact our customer service center.