Table 62. Input Connector And Pin Assignment; Table 63. Pdb Cable Length - Intel S2600CW Technical Product Specification

Table of Contents

Advertisement

Power Supply Specification Guidelines
Pin
A1
GND
A2
GND
A3
GND
A4
GND
A5
GND
A6
GND
A7
GND
A8
GND
A9
GND
A10
+12V
A11
+12V
A12
+12V
A13
+12V
A14
+12V
A15
+12V
A16
+12V
A17
+12V
A18
+12V
A19
PMBus* SDA
A20
PMBus* SCL
A21
PSON
A22
SMBAlert#
A23
Return Sense
A24
+12V remote Sense
A25
PWOK
*The compatibility Pin is used for soft compatibility check. The two compatibility pins are connected directly.
10.3.2.2
Output Wire Harness
The power distribution board has a wire harness output with the following connectors.
Listed or recognized component appliance wiring material (AVLV2), CN, rated min 85°C shall
be used for all output wiring.
From
Power Supply cover exit hole
Power Supply cover exit hole
Power Supply cover exit hole
Power Supply cover exit hole
138

Table 62. Input Connector and Pin Assignment

Name

Table 63. PDB Cable Length

Length,
To connector
mm
#
280
P1
300
P2
500
P3
900
P4
Intel® Server Board S2600CW Family TPS
Pin
B1
GND
B2
GND
B3
GND
B4
GND
B5
GND
B6
GND
B7
GND
B8
GND
B9
GND
B10
+12V
B11
+12V
B12
+12V
B13
+12V
B14
+12V
B15
+12V
B16
+12V
B17
+12V
B18
+12V
B19
A0 (SMBus* address)
B20
A1 (SMBus* address)
B21
12V stby
B22
Cold Redundancy Bus
B23
12V load share
B24
No Connect
B25
Compatibility Pin*
No of
pins
24
Baseboard Power Connector
8
Processor 0 connector
8
Processor 1 connector
5
Power FRU/PMBus* connector
Name
Description
Revision 2.4

Advertisement

Table of Contents
loading