nearby Compass/heading device is checked for any change in deviation after
installing the terminal.
BDU mounting information
1. The BDU can be mounted in either the horizontal or vertical position.
2. Install the BDU in a protected but ventilated area. Allow at least a 1-inch space
around top and sides to provide adequate cooling.
3. Mount the terminal onto a flat surface using at least four screws or bolts (not
supplied). Use screws or bolts with a diameter between 3.5 to 4mm. Vibration-
resistant screws or lock washers should be used.
V+ DC Volts
Source
(fused)
Package materials
16
Dimension BETWEEN Mounting Holes: 271mm
Figure 2-1. BDU - mounting dimensions in mm.
V- DC Volts
Source
Figure 2-2
BDU Wiring Diagram
RSI
Thuraya Orion IP BDU
+
-
RSI = Remote Switch Input
Chassis
-
Gnd Point
Vessel Ground