Henny Penny
7-6. CONTACTOR
(continued)
Replacement:
7-7. DRIVE MOTOR
REPLACEMENT
698
6. Check voltage as follows:
Test Points
from terminal 29 to 28
from terminal 27 to 28
from terminal 27 to 29
If contactor proves defective:
7. Remove the four screws securing the contactor to the
bracket and remove contactor.
8. Install new contactor, replace wires, and replace side
panel.
9. Restore power to unit.
1. Remove electrical power to unit.
Remove electrical power supplied to the unit by unplug-
ging the unit, or by turning off the wall circuit breaker, or
electrical shock could result.
2. Remove rod and discs from unit. (See Section 3-3.)
3. Cut the three wires from the motor.
4. Using 9/16" socket, remove the bolts securing the
motor to the bracket, and pull motor from unit.
SCR-6/8
Results
The voltage
should read the
same at each terminal.
7-5