  • Page 1 Web Hub WH-2400M WH-2400S Web/SNMP Manageable Ethernet Hub...
  • Page 3: Fcc Warning

    Trademarks Copyright © PLANET Technology Corp. 1998. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. FCC Warning This device has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 5: Table Of Contents

    Table of Contents ............1-1 HAPTER INTRODUCTION About Web Hub ................1-1 Key Features ..................1-2 2. H ..........2-1 HAPTER ARDWARE VERVIEW Front Panel Layout................2-1 Ports ....................... 2-2 LEDs ...................... 2-3 Common LEDs ................... 2-4 Unit ID ....................2-5 Exclusive LEDs .................. 2-7 Rear Panel Layout ................2-11 3.
  • Page 6 HP Overview Platform ................ 5-2 Web Management ................... 5-3 ...........A-1 PPENDIX ECHNICAL PECIFICATIONS...
  • Page 7: Introduction

    The LED Indicator Panel provides an effective means for monitoring the network with extensive LED indicators for easy viewing ports Activity, Utilization, Collision and other functions. WH-2400M WH-2400S WH-2400S Figure 1.1 Web Hub WH-2400M/WH-2400S WH-2400M / WH-2400S User's Manual...
  • Page 8: Key Features

    Key Features • 24 10Base-T (RJ-45) ports. • 1-AUI Backbone port. • Μemory for Network Management (WH-2400M only) ♦ Flash memory: 1MB ♦ EEPROM: 8KB ♦ DRAM: 2MB ♦ CPU: RISC CPU at 20MHz. • (LRSC) Long Range Star Cascaded Hub Stack providing: ♦...
  • Page 9 • Automatic Unit I.D. setting on all the hubs in the stack. • Simple and Cost-effective upgrade by means of a WH-2400M master hub to Switch 1000M swap, without losing on the port-level management. • Unmatched price/performance – Value for money.
  • Page 10 Introduction PLANET Web Hub...
  • Page 11: Chapter 2. Hardware Overview

    Front Panel Layout The Master Hub’s (WH-2400) front panel combines an LED Panel, 24 MDI-X ports and an MDI-II port as shown in Fig. 2.1. Figure 2.1 WH-2400M Font Panel. WH-2400M / WH-2400S User's Manual...
  • Page 12: Ports

    Figure 2.2 WH-2400S Font Panel. Ports There are 25 10Mbps UTP ports on the front panel of both WH-2400M and WH- 2400S. In the case of WH-2400M ports 1~8 are shared M-Link ports for Uplink Slave hubs (WH-2400S) network traffic. As well as Management traffic these ports could also be used to connect workstations as any other MDI-X ports.
  • Page 13: Leds

    Hardware Overview LEDs The LED panels for both, WH-2400M and WH-2400S are a storehouse of information, which visually indicate the physical connections, traffic flow, Utilization, and Collision. The LED functions are described under Common LEDs for those that are common to both WH-2400M and WH-2400S and Exclusive LEDs for those are exclusive to either WH-2400M or WH-2400S.
  • Page 14: Common Leds

    Hardware Overview Common LEDs Most LEDs that are common to both WH-2400M & WH-2400S and are explained in this section. Port There is an LED for every port indicating the following status conditions of the port. The legend located on the left of the ports LED shows the relationship between the LEDs and the ports status at any given time.
  • Page 15: Unit Id

    The ID LED indicates the assigned Unit ID number. In a stand-alone case, the ID number will be read as “0”. Figure 2.8 WH-2400M ID LED. When slave hubs are cascaded to the Master hub they are automatically assigned the numbers 2~9, while the Master assumes ID “1”...
  • Page 16: Collision Ratio

    Collision Ratio = (number of packets collided / number of packets transmitted) * 100. FCS/Align Err The FCS/Align Err LED glows, amber indicating there were corrupted packets during transmissions. Alignment error occurs, when not all the bytes in a packet are received. Figure 2.11 FCS/Align LED. PLANET Web Hub...
  • Page 17: Exclusive Leds

    The Late Collision LED glows, amber when collisions occur after 512 bits are received causing an incomplete transmission. Figure 2.13 Late Collision. Exclusive LEDs Some LEDs are exclusive to either WH-2400M or WH-2400S, their purpose is described in this section. WH-2400M / WH-2400S User's Manual...
  • Page 18 Hardware Overview Master The Master LED is exclusive to WH-2400M and glows green in color indicating the hub is a Master hub. The LED at port 24 glows, green indicating the Uplink. Figure 2.14 Master. SNMP The SNMP LED is exclusive to WH-2400M and glows green in color indicating the hub is being monitored through the SNMP management program.
  • Page 19 Hardware Overview The WWW LED is exclusive to WH-2400M and glows green in color indicating the hub is being monitored through the WWW management program. The LED at port 24 glows, green indicating the Uplink. Figure 2.16 WWW. Out-Of-Band The Out-Of-Band LED is exclusive to WH-2400M and glows green in color indicating the hub is being monitored through the Console management program.
  • Page 20 Slave is connected to one of the Master’s M-Link ports (1~8). Figure 2.18 M-Link LED. Mgmt When a WH-2400S slave is connected to one of WH-2400M’s M-Link ports (1~8) and is being managed through a management program, both WH-2400S’s M-Link and Mgmt LEDs glows green in color.
  • Page 21: Rear Panel Layout

    Hardware Overview 2-11 Rear Panel Layout On WH-2400M’s rear panel there is an AUI port for linking to a backbone and a Console Port (RS 232 Port) used in Out-Of-Band SNMP management. Figure 2.20 HubWH-2400M Rear Panel. On WH-2400S’s rear panel there is an AUI port for linking to a backbone.
  • Page 22 2-12 Hardware Overview PLANET Web Hub...
  • Page 23: Chapter 3. Installation

    Then place the device into the 19 inch rack and affix it with screws. Please ensure that the ventilation holes remain unblocked. Figure 3.1 Rack Mounting. WH-2400M / WH-2400S User's Manual...
  • Page 24: Star Topology

    Allows up to 8 Managed Slave hubs to be uplinked through ports 1~8. • Maximum 100 meter segments allow very flexible physical configurations. • Additional unmanaged hub can be linked to ports 9~24. Star Cascading M-Link Ports Figure 3.2 Star Topology. PLANET Web Hub...
  • Page 25: Using The Aui Port

    LAN. Figure 3.3 AUI Port. Using the Console Port Connect an RS 232 serial cable to the Console Port of WH-2400M and to a PC or Notebook computer’s available COM port. Figure 3.4 Console Port. Connecting Other Devices Other devices such as Workstations, Servers, Switches etc.
  • Page 26: Connecting Workstations

    Installation Connecting Workstations Workstations can be connected to Web Hub’s Master or Slaves MDI-X Ports (UTP Port) as shown in Fig. 3.5. Figure 3.5 Connecting Workstations. PLANET Web Hub...
  • Page 27: Connecting Switches

    Installation Connecting Switches A Web Hub domain can be connected to switch as shown in Fig. 3.6. Figure 3.6 Connecting Switches. WH-2400M / WH-2400S User's Manual...
  • Page 28 Installation PLANET Web Hub...
  • Page 29: Chapter 4. Console Operations

    To configure the system, connect an RS-232 serial cable to a COM port on a PC or notebook computer and to the serial port of the Master Hub as show below. Note: Do not use a null mode cable. Figure 4.1 Connecting a PC via Console Port. Terminal Program WH-2400M / WH-2400S User's Manual...
  • Page 30 Console Operations A Terminal Program is required to communicate with WH-2400M internal software. Windows95 provides a suitable program called "HyperTerminal" and is accessed from the Start menu. Click START, then Programs, Accessories and then HyperTerminal. Figure 4.2 Terminal Program. An MS-DOS type terminal program can also make the connection with the Master Hubs built in software, however this section describes using Windows 95s HyperTerminal.
  • Page 31 Since you won’t be dialing out via a modem you only need to set the COM port. Click the arrow at the right of the “Connect using” label. Figure 4.5 Phone Number Screen. WH-2400M / WH-2400S User's Manual...
  • Page 32 In the final screen all settings must be set correctly, Bits/sec “9600”, Data bits “8”, Parity “None”, Stop bits “1” and Flow Control “Hardware” as in the figure below. Click the OK button and the link to Web Hub will be complete. Figure 4.7 Port Settings. PLANET Web Hub...
  • Page 33: Login Screen

    Main Menu. WH-2400M/WH-2400S W EEEEE BBBBB U BBBBB W W W E EEE BBBB HHHH U U BBBB EEEEE BBBBB BBBBB User name Password Figure 4.8 Main Banner of Run Time Local Consule Menu. WH-2400M / WH-2400S User's Manual...
  • Page 34: Main Menu

    Select HELP, to view keyboard commands. WH-2400M/WH-2400S -Main Menu- System Information Management Setup Device Control User Authentication System Utility EXIT HELP Use <Tab> key to select the item, and press the <Enter>... Figure 4.9 Main Menu of Run Time Local Console. PLANET Web Hub...
  • Page 35 [Enter] : Confirm Input [TAB] : Go to next Tabstop <Ctrl>-Z : Go to next Tabstop <Ctrl>-W : Go to previous Tabstop <Ctrl>-S/<Ctrl>-A : Select/Toggle <FIELD> value [ESC] TO GO BACK Figure 4.10 Help Menu. WH-2400M / WH-2400S User's Manual...
  • Page 36: System Information Menu

    0 days 0 hr. 0 min. 0 sec. System Contact: System Name: [10Mbps Ethernet Hub System Location: System Manager: Web and SNMP MIB Supported: RFC 1213, RFC1215, RFC1516, PLANET proprietary MIB SAVE EXIT TO MAIN MENU HELP Figure 4.11 System Information Menu PLANET Web Hub...
  • Page 37: Management Setup Menu

    Serial Port Configuration SNMP Community Setup Trap Manager Community Setup Web Configuration EXIT TO MAIN MENU HELP Use <Tab> key to select the item, and press the <Enter>... Figure 4.12 Management Setup Menu of WH-2400M Console. WH-2400M / WH-2400S User's Manual...
  • Page 38 -Network Configuration Menu- Network Interface: <1> Interface Type: MAC Address: 00-E0-95-00-00-06 Configuration: Current IP Address: 210.68.0.98 [210.68. 0.98] Subnet Mask: 255.255.255.0 [255.255.255.0] Default Gateway: 0.0.0.0 [0.0.0.0] SAVE EXIT TO MAIN MENU HELP Figure 4.13 Network Configuration Menu. PLANET Web Hub...
  • Page 39 -Serial Port Configuration Menu- Operation Mode: <CONSOLE>Mode Baud Rate: 9600 Bps Character Size: Bits Parity: Parity Stop Bits: Bits *** Fixed configuration, can not be changed. *** EXIT TO MAIN MENU HELP Figure 4.14 CONSOLE Mode Configuration Menu WH-2400M / WH-2400S User's Manual...
  • Page 40 SNMP Community Name Access Right Status ---------- --------------------------------- ------------------ --------------- public <Read Only> <Disable> private <Read/Write> <Enable> ------- ------------------------------ ----------------- ------------- Input: <Read Only> <Disable> ADD DELETE UPDATE EXIT TO MAIN MENU HELP Figure 4.15 SNMP Community Configuration Menu PLANET Web Hub...
  • Page 41 [0.0.0.0] <Inactive> [0.0.0.0] <Inactive> [0.0.0.0] <Inactive> [0.0.0.0] <Inactive> [0.0.0.0] <Inactive> [0.0.0.0] <Inactive> ***Use <Tab> or arrow keys to select index <Enter> to EDIT*** EXIT TO MAIN MENU HELP Figure 4.16 Trap Manager Community Configuration Menu WH-2400M / WH-2400S User's Manual...
  • Page 42 Enable/Disable. Save the new setting. ♦ Enable: Web Management is enabled. ♦ Disable: Web Management is disabled. WH-2400M/WH-2400S -Web Configuration Menu- Web Management Function: <Enable> SAVE EXIT TO MAIN MENU HELP Figure 4.17 Web Configuration Menu PLANET Web Hub...
  • Page 43: Device Control Menu

    WH-2400M/WH-2400S -Device Control Menu- Repeater Group Control/Status Repeater Port Control/Status EXIT TO MAIN MENU HELP Use <Tab> key to select the item, and press the <Enter> Figure 4.18 Device Control Menu WH-2400M / WH-2400S User's Manual...
  • Page 44 [ 1 ] ----------------------------------------------- Group Status: Operation Group Admin. State: < Enable > Device Serial Number: 00000000 Device Name: Device Role: Master PRE GROUP NEXT GROUP SAVE EXIT TO MAIN MENU HELP Figure 4.19 Repeater Group Control/Status Menu PLANET Web Hub...
  • Page 45 Auto Polarity Reversal Enable Administrator State < Disable > Port Name: [ ] (max 8 bytes) PRE GROUP NEXT PORT PRE GROUP NEXT GROUP SAVE EXIT TO MAIN MENU HELP Figure 4.20 Repeater Port Control/Status Menu WH-2400M / WH-2400S User's Manual...
  • Page 46: User Authentication Menu

    User Name Password Privilege -------- ------------- ----------- ----------- [HUB10] [*****] Read/Write [GUEST] [*****] Read Only ***Use <Tab> key to select the item, and press the <Enter>*** SAVE EXIT TO MAIN MENU HELP Figure 4.21 User Authentication Menu PLANET Web Hub...
  • Page 47 User Authentication Menu - 1- User Name Password Privilege ------------- ----------- ----------- [HUB10] [*****] Read/Write ***Use <Tab> key to select the item, and press the <Enter>*** DELETE UPDATE EXIT TO MAIN MENU HELP Figure 4.22 User Authentication Menu-1 WH-2400M / WH-2400S User's Manual...
  • Page 48: System Utility

    WH-2400M/WH-2400S -System Utility Menu- System Download System Restart Factory Reset EXIT TO MAIN MENU HELP Use <Tab> key to select the item, and press the <Enter>... Figure 4.23 System Utility Menu of Web Hub Local Console PLANET Web Hub...
  • Page 49 EXIT TO MAIN MENU HELP Figure 4.24 System Download Menu The download will start after restarting the system. If a download is incomplete, it may be necessary to do a Factory Reset, thereby loosing all custom settings. WH-2400M / WH-2400S User's Manual...
  • Page 50 Enter. The system will reload and the logon screen will prompt for user name and password. WH-2400M/WH-2400S -System Restart Menu- System Restart: < Cold Start > EXECUTE EXIT TO MAIN MENU HELP Figure 4.25 System Reset Menu PLANET Web Hub...
  • Page 51 255.255.255.0 Default Gateway 0.0.0.0 User Authentication Configuration: <Not Reset > Factory Default: User Name Password Privilege ------------- ----------- ------------ HUB10 HUB10 Read/Write EXECUTE EXIT TO MAIN MENU HELP Figure 4.26 Factory Reset System Configuration Data WH-2400M / WH-2400S User's Manual...
  • Page 52 4-24 Console Operations PLANET Web Hub...
  • Page 53: Snmp And Web Management: Overview

    Monitoring the Status of hubs and their ports is essential in order to analyze and optimize overall network performance. • Security Security has several purposes such as protecting the systems configuration from being inadvertently altered by unknowledgeable users to safeguarding sensitive information from unauthorized persons. WH-2400M / WH-2400S User's Manual...
  • Page 54: In-Band

    Out-of-band management is accomplished through the Console Management Program via the Console (serial) port and cannot be accomplished from within the network. Managing from SNMPc Platform HP Overview Platform HP Overview Platform is Hewlett Packard’s management program. PLANET Web Hub...
  • Page 55: Web Management

    SNMP and Web Management: Overview Web Management WH-2400M embedded web server integrates HTML forms and Java™ applets for dynamic, real-time status update and monitoring and Standard Web Server security for total network protection. For a complete understanding of Web Management, see Web Hub Software Manual.
  • Page 56 SNMP and Web Management: Overview PLANET Web Hub...
  • Page 57: Technical Specifications

    Appendix A A p p e n d i x A Technical Specifications WH-2400M / WH-2400S User's Manual...
  • Page 59 SNMP Network -Supporting standard RFC 1157 SNMP, RFC 1213 MIB-II, RFC Monitoring 1516 Repeater MIBs, and PLANET proprietary MIBs -Supporting RFC 1757 RMON Groups 1,2,3, and 9 * -In-band & Out-of-band management* -Bootp server and TFTP software download supported...
  • Page 60 Appendix A EMWH2400M/S PLANET Web Hub...