Component Replacement Procedures

When performing a component replacement procedure; ensure any
escaping water is caught in a container and does flow onto any electrical
components.
When draining water from tank using the tap, some water will remain in the
tank.
 If it is necessary to remove the BWU from the wall, take care to keep the
BWU standing upright to prevent water escaping from top fittings onto
electrical components.
 If replacing an element, lock the tap open, remove the wiring connector
from the water level probe and restore power. This will allow cold water
to enter the tank and cool any remaining boiling water.
Isolate power before performing any component replacement procedures
When performing any component replacement procedure, water of an
elevated temperature may be present. Ensure PPE is worn to prevent the
risk of scalding.
All BWUs
Jacket Surround (Procedure 1)
1. Isolate power supply to BWU.
2. Remove four screws retaining jacket surround and pull jacket away from BWU to
remove. Two screws are located on top of BWU and two screws are located
underneath BWU
3. Complete reassembly in reverse order of above.
WARNING 701 Series: - When refitting the jacket surround, ensure that the boiling
water outlet tube is positioned correctly in spout.
Tap (Procedure 2A) 702 & 703 Tap replacement
1. Isolate power and water supplies to BWU.
2. Operate tap lever until water ceases to flow from tap.
3. Support tap and unscrew tap union in a clockwise direction to remove tap.
4. Complete reassembly in reverse order of above.
5. Check for leaks.
TM063 701, 702 & 703 Series Boiling Water Unit Service Instructions
Revision D: Feb 2017
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
46

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

702107030370105702077030770215 ... Show all

Table of Contents