SiBE05-722EE
2.2

RK(X)S25/35G2V1B

Main PCB (PCB2)
1) S10
2) S20
3) S30
4) S40
5) S50
6) S70
7) S80
8) S90
9) HL3, HN3
10)HR2
11)FU1, FU2
12)LED A
13)V1
14)J5
15)J8
16)SW1
HR2
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for the electronic circuit. Improper operation may occur if you cut any of
them.
Printed Circuit Board Connector Wiring Diagram
Connector for filter PCB
Connector for electronic expansion valve coil
Connector for compressor
Connector for overload protector
Connector for magnetic relay
Connector for fan motor
Connector for four way valve coil
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
Connector for filter PCB
Connector for reactor
Fuse (3.15 A, 250 V)
LED for service monitor (green)
Varistor
Jumper for improvement of defrost performance
∗ Refer to page 121 for details.
Jumper for facility setting
∗ Refer to page 120 for details.
Forced cooling operation ON/OFF button
∗ Refer to page 116 for details.
S30
FU1
HN3
HL3
J5
S10
J8
S90
S80
V1
S20
Outdoor Unit
S40
S50
LED A
SW1
S70
FU2
2P203198-1