Retrieve LED

This command returns the status of the LEDs in the specified module. The LEDs
are reported in order from top to bottom.
Syntax
RTRV-LED:[tid]:[aid]:ctag;
Parameter
[aid]
Refer to the SSU-2000 User's Guide for a detailed description of each module's
LED indicators.
Response Format
If the module does not support this command, the DENY response is returned.
^^^"aid:hwpart,num,led1,...,ledn" <cr lf>
where:
= module access identifier
aid
hwpart = the hardware part number for the module
num = total number of LEDs in the specified module
ledn = LED status [OFF | GRN | AMB | RED | BLK], where OFF = LED is off,
GRN = LED is green, AMB = LED is amber, RED = LED is red, BLK = LED is
blinking
Example
SSU_2000 05-01-13 19:26:34
M
100 COMPLD
"S1A01:23413016-000-0,7,GRN,GRN,GRN,OFF,OFF,GRN,OFF"
"S1A02:23413012-000-0,8,GRN,GRN,GRN,GRN,AMB,AMB,OFF,GRN"
"S1A03:23413019-000-0,4,GRN,GRN,GRN,GRN"
"S1A04:23413014-002-0,8,GRN,GRN,OFF,OFF,OFF,OFF,OFF,OFF"
"S1A06:23413305-000-0,8,GRN,GRN,OFF,AMB,OFF,AMB,OFF,AMB"
"S1A07:23413305-000-0,8,GRN,GRN,OFF,GRN,OFF,GRN,OFF,AMB"
"S1A10:23413306-000-0,7,GRN,GRN,GRN,OFF,OFF,OFF,OFF"
"S1A12:23413015-000-0,7,GRN,GRN,OFF,OFF,OFF,GRN,OFF"
;
12713020-003-2 Revision F.01 – January 2007
Value
Retrieves all LED data from the shelf.
ALL
Retrieves LED data from the specified module.
SxAy