Chapter 3 ICS Command Reference
TDEV
Example
SSU_2000->tdev 1a9-1
TDEV for 1A09-01, on Clock A:
Start Time: 2001-06-19T01:00:00
Stop Time:
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV (
The TDEV ( 1000.00 sec) is 0.24
The TDEV ( 3000.00 sec) is 0.62
The TDEV ( 6000.00 sec) is 1.22
The TDEV (10000.00 sec) is 1.60
228 SSU-2000e Technical Reference
2001-06-19T13:57:00
0.10 sec) is 0.56
0.30 sec) is 0.33
0.60 sec) is 0.24
1.00 sec) is 0.18
3.00 sec) is 0.11
6.00 sec) is 0.09
10.00 sec) is 0.07
30.00 sec) is 0.06
60.00 sec) is 0.07
100.00 sec) is 0.09
300.00 sec) is 0.14
600.00 sec) is 0.19