Symmetricom SSU-2000e Technical Reference page 202

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

Chapter 3 ICS Command Reference
MTIE
Only the values available in the interval between the start and stop times
are output. For the first three hours of operation after an input is enabled,
the values are displayed on a 1-minute boundary. After the first three
hours of operation, the data is displayed on a 1-hour boundary. The
returned MTIE values have a timestamp that corresponds to the nearest
minute or hour boundaries.
MTIE xAy-z [{A| B}] HISTORY [count]
A| B specifies Clock A or Clock B. The default is the selected clock
output. This command displays the one-day MTIE history for the last one
to 100 days.
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation
Level 4
Same as Level 3 operation
Remarks Since MTIE involves intensive calculations, you can only specify one
port.
Related
None
RestrictionsNone
Example
SSU_2000+>mtie 1A10-02
MTIE for 1A09-01, on Clock A:
Start Time: 2001-06-24T19:00:00
Stop Time:
The MTIE (
The MTIE (
The MTIE (
The MTIE (
The MTIE (
The MTIE (
The MTIE ( 10000.00 sec) is 22
The MTIE (100000.00 sec) is 22
2001-06-25T18:20:49
TL1A
202 SSU-2000e Technical Reference
2001-06-25T18:20:00
0.05 sec) is 5
0.10 sec) is 5
1.00 sec) is 6
10.00 sec) is 7
100.00 sec) is 12
1000.00 sec) is 13
1A05 Rep Pos Set by Rec, Information Locked,
12713140-003-2 Revision E.01 – January 2007

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000e

This manual is also suitable for:

Sdu-2000e

Table of Contents