Electrical

High Voltage Settings
Note: The adjustment value is specified on the information label attached to the High Voltage PWB.
Using Simulation 8-01 (DV Bias Setting) & Sim 8-02 (MC Grid Bias Setting), enter the values
specified, especially after replacing the PCU PWB, EEPROM or following U2 trouble.
DEVELOPING BIAS VOLTAGE – SIMULATION 08-01
Item
DVB_K
Developing Bias Adjustment value
DVB_K_PLUS
Reverse Developing Bias Voltage
MAIN CHARGE GRID VOLTAGE – SIMULATION 08-02
Item
Content
Main Charge
GB_K
Grid Voltage
Adjustment
22
Content
Default
Setting
Range
MXM904
200 - 1000
575
Setting
Default
Range
0-750
496
0-250
164
Monitor
MXM1054
Connector
MXM1204
& PIN
605
CN2 Pin 7 -595 +/- 5V
SHARP
Monitor
Actual
Connector
Output
& PIN
Voltage
-500 +/-
5V
CN2 Pin
11
-150 +/-
5V
Actual Output Voltage
MXM1054
MXM904
MXM1204
-625 +/-
5V