12.7 Cleaning the inlet hose and the valve filter
1.
1
2
3
Remove the inlet hose from the tap and clean
its internal valve.
3.
Clean the valve filter on the back of the
appliance with a toothbrush.

12.8 Emergency emptying out

If the appliance does not drain the water,
proceed as follows:
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. If necessary, wait until the water has
cooled down.
4. Place a bowl on the floor and put the
end of the emergency emptying
hose into the bowl. Remove its cap.
The water should drain into the bowl.
5. When the bowl is full, put the cap
back on the emergency hose.
6. Empty the bowl. Repeat the
procedure until water stops flowing.
2.
Remove the inlet hose from the appliance by
loosening the ring nut.
4.
20°
When you reconnect the hose to the back of
the appliance, do not turn the inlet hose
downwards, but turn it left or right depending
on the position of your water tap.
7. Clean the pump if necessary as
previously described ("Cleaning the
drain filter").
8. Ensure the cap is back on the
emergency emptying hose and insert
back into position.
When you drain the water with the
emergency drain procedure, you must
activate the drain system again:
1. Put 2 litres of water in the main wash
compartment of the detergent
dispenser.
2. Start the programme to drain the
water.

12.9 Frost precautions

If the appliance is installed in an area
where the temperature can be less than
ENGLISH
21
45°