Shure Publications | User Guides | AD2
http://pubs.shure.com/guide/AD2/en-US
range of the transmitter.
RF Output
On: RF signal is active
Mute: RF signal is inactive
Audio Menu
Offset
Adjust Offset level to balance mic levels
when using two bodypacks for frequency
diversity.
MuteMode
When enabled, the power switch is
configured as a mute switch for the audio:
Power switch on: audio signal on
Power switch off: audio signal muted
Tone
Transmitter will generate a continuous test
tone. The tone can be set to 400 Hz or
1000 Hz.
Level
When enabled, allows for adjustment of
the output level of the test tone.
Utilities Menu
Dev ID
Assign a device ID of up to 9 letters or
numbers.
Lock
Locks the transmitter controls and power
switch.
Marker
When enabled, press the enter button to
drop a marker in Wireless Workbench.
Battery
Displays battery information:
Battery: The chemistry type of for the
installed battery (Shure Rechargeable,
Alkaline, Lithium, NiMH)