Fujitsu AR*G45LHTA series Technical Manual page 30

Duct type
Hide thumbs Also See for AR*G45LHTA series:
Table of Contents

Advertisement

3) Room temperature control for heating
Depending on the installed environment, correction of the room temperature sensor may be
required.
Select the appropriate control setting according to the installed environment.
Setting description
Standard
Higher control
Slightly higher control
Lower control
4) Auto restart
Enable or disable automatic restart after a power interruption.
Setting description
Enable
Disable
* Auto restart is an emergency function such as for power outage etc. Do not attempt to use
this function in normal operation. Be sure to operate the unit by remote controller or external
device.
5) Room temperature sensor switching
(Only for wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
Setting description
Indoor unit
Both
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
*Remote controller sensor must be turned on by using the remote controller.
6) Cool air prevention
This setting is to disable the cold air prevention function during heating operation. When
disabled, the fan setting will always follow the setting on the remote controller. (Excluding
defrost mode)
Setting description
Enable
Disable
(  ... Factory setting)
Function number
Setting value
31
(  ... Factory setting)
Function number
Setting value
40
(  ... Factory setting)
Function number
Setting value
42
(  ... Factory setting)
Function number
Setting value
43
- (01 - 27) -
00
01
02
03
00
01
00
01
00
01