LG LS-H0560CL Service Manual page 20

Table of Contents

Advertisement

4. Checking the Drainage and Connecting the cable to Indoor unit
1) Checking the Drainage
1. Remove the Grille from the cabinet.
• Set the up-and-down air direction louver to open
position (horizontally) by finger pressure.
• Remove the securing screws.
• To remove the Grille, pull lower the left and right
side of the grille toward you (slightly tilted) and lift
it straight upward (Two tabs on the top inside
edge of the grille are clear of their slots).
2. Check the drainage.
• Pour a glass of water on the evaporator.
• Ensure if water flows drain hose of indoor unit
without any leakage.
(Both the left and the right side)
Pull on the right and the left side.
—20—
Screw