B: Misfeed in the fusing area
1
Lower the fusing unit release
lever.
2
Gently remove the misfed paper
from under the fusing unit as
shown in the illustration. If the
paper cannot be removed, proceed
to "C: Misfeed in the transport
area".
The fusing unit is hot. Do not
touch the fusing unit when
removing misfed paper. Doing
so may cause a burn or other
injury.
• Do not touch the photoconductive drum (green portion) when
• Do not remove the misfed paper from above the fusing unit.
3
Raise the fusing unit release lever and then close the side
cover by pressing the round projections near the side cover
open button. The misfeed (
(
) indicator will light up.
removing the misfed paper. Doing so may cause smudges on
copies.
Unfixed toner on the paper may stain the paper transport
area, resulting in smudges on copies.
Fusing unit release lever
) indicator will go out and the start