4.7.2.6 VOR/LOC Composite
Pin Name
VOR/LOC COMPOSITE OUT
With a Standard VOR Test Signal applied, VOR/LOC COMPOSITE OUT is 0.5 ±0.1 V
load. With a standard localizer centering test signal applied, VOR/LOC COMPOSITE OUT is 0.350
±0.05 V
into a 10 kΩ load.
RMS
4.7.2.7 Glideslope Composite
Pin Name
GLIDESLOPE COMPOSITE OUT
(011-01105-20 AND 011-01105-30 ONLY)
With a standard glideslope centering test signal applied, GLIDESLOPE COMPOSITE OUT is
0.35 +/- 0.05 Vrms into a 10k Ω load.
4.7.2.8 ILS Energize
Pin Name
ILS ENERGIZE*
INACTIVE: Floating (can be pulled up to externally sourced Vout in the range 0 ≤ V out ≤ 3 3VDC)
Leakage current in the INACTIVE state is typically ≤ 10 uA to ground
ACTIVE: Vout ≤ 0.5VDC with ≤ 2 0 mA sink current
Sink current must be externally limited to 20 mA max
Page 4-22
Revision T
Connector
Pin
P602
8
into a 10 kΩ
RMS
Connector
Pin
P602
58
Connector
Pin
P602
29
GIA 63 Installation Manual
I/O
Out
I/O
Out
I/O
Out
190-00303-05