1.4.9 Glideslope Specifications
Characteristics
Sensitivity
Centering Accuracy
Selectivity
Standard deflection
Flag
1.4.10 Power Requirements
Characteristics
Input Voltage Range
Power Requirements for P601
(COM Connector)
011-01105-20,
011-01105-30 units
Power Requirements for P601
(COM Connector)
Superflag Power
Requirements for P605
(Main 2 Connector)
Power Requirements for P605
(Main 2 Connector)
Page 1-8
Revision T
At –93 dBm, deviation output shall not be less than 60% of
standard deflection when glideslope deviation test signal is
applied.
0 ± .0091 ddm or 0 ± 7.8 mV.
6 dB BW is greater than 17 kHz.
69 dB BW is less than 132 kHz.
a) With a standard deflection 'FLY DOWN' condition (90 Hz
dominant), the output shall be -78 mV ± 7.8 mV.
b) With a standard deflection 'FLY UP' condition (150 Hz
dominant), the output shall be +78 mV ± 7.8 mV.
The GS Course Deviation Flag must be flagged:
a) When the level of a standard deviation test signal
produces 50% or less of standard deflection of the
deviation indicator.
b) In the absence of 150 Hz modulation.
c) In the absence of 90 Hz modulation.
d) In the absence of both 90 Hz and 150 Hz modulation.
e) In the absence of RF.
28 Vdc for P601 (14/28 Vdc for 011-01105-20 and
011-01105-30 units)
14/28 Vdc for P605
See the Environmental Qualification Form for details on
surge ratings and minimum/maximum operating voltages.
0.3 A max @ 27.5 Vdc (not transmitting);
4.3 A max @ 27.5 Vdc (transmitting)
0.6 A max @ 13.75 Vdc (not transmitting);
6.0 A max @ 13.75 Vdc (transmitting)
Power depends upon loads present on Superflag output pins
(see Sections 4.7.2.1 and 4.10.7)
1.0 A max @ 27.5 Vdc (Without Superflags Active)
2.0 A max @ 13.75 Vdc (Without Superflags Active)