Model - Daikin FTN25JXV1 Technical Manual

Unit, wall mounted ftn-j/ftyn-j series
Table of Contents

Advertisement

Performance Data
Model: FTYN80FXV1 - RQ71CXY1
Cooling Mode
AFR
EWB
EDB
(CFM)
TC
21°C
7.18 4.68 2.00 6.93 4.55 2.16 6.67 4.43 2.34 6.40 4.30 2.54 5.88 4.01 2.75 5.43 3.77 3.04
24°C
7.19 5.60 2.00 6.94 5.47 2.16 6.68 5.34 2.34 6.41 5.21 2.54 5.89 4.87 2.76 5.45 4.59 3.04
16°C
27°C
7.25 6.35 2.00 7.01 6.21 2.17 6.76 6.06 2.35 6.51 5.90 2.55 6.01 5.49 2.76 5.59 5.16 3.05
30°C
7.47 7.47 2.01 7.26 7.26 2.18 7.04 7.04 2.36 6.81 6.81 2.57 6.32 6.32 2.79 5.91 5.91 3.08
24°C
7.92 4.37 2.03 7.65 4.26 2.20 7.37 4.14 2.38 7.07 4.03 2.58 6.50 3.75 2.80 6.01 3.53 3.09
27°C
7.93 5.00 2.03 7.65 4.88 2.20 7.37 4.77 2.38 7.08 4.66 2.58 6.51 4.35 2.80 6.02 4.13 3.09
500
19°C
30°C
7.94 6.16 2.03 7.67 6.03 2.20 7.40 5.90 2.38 7.12 5.76 2.59 6.55 5.38 2.81 6.08 5.10 3.09
33°C
8.04 8.04 2.04 7.77 7.77 2.21 7.52 7.52 2.39 7.27 7.27 2.60 6.72 6.72 2.82 6.29 6.29 3.11
27°C
8.72 4.27 2.07 8.42 4.17 2.24 8.11 4.07 2.43 7.79 3.95 2.63 7.17 3.68 2.86 6.63 3.47 3.15
30°C
8.72 5.21 2.07 8.42 5.10 2.24 8.11 4.98 2.43 7.79 4.86 2.63 7.17 4.55 2.86 6.64 4.32 3.15
22°C
33°C
8.73 6.08 2.07 8.42 5.97 2.24 8.12 5.85 2.43 7.80 5.73 2.63 7.18 5.38 2.86 6.65 5.11 3.15
36°C
8.75 6.90 2.07 8.47 6.76 2.24 8.17 6.62 2.43 7.87 6.47 2.64 7.26 6.07 2.86 6.75 5.76 3.16
21°C
7.48 4.88 2.02 7.21 4.75 2.18 6.93 4.63 2.36 6.65 4.50 2.56 6.10 4.19 2.78 5.63 3.94 3.06
24°C
7.50 5.92 2.02 7.23 5.78 2.18 6.96 5.64 2.36 6.68 5.50 2.56 6.13 5.13 2.78 5.67 4.85 3.07
16°C
27°C
7.59 6.73 2.02 7.33 6.57 2.19 7.08 6.40 2.37 6.83 6.21 2.57 6.30 5.77 2.79 5.87 5.39 3.08
30°C
7.91 7.91 2.04 7.68 7.68 2.21 7.44 7.44 2.39 7.20 7.20 2.60 6.67 6.67 2.82 6.24 6.24 3.12
24°C
8.24 4.62 2.05 7.94 4.50 2.22 7.65 4.38 2.40 7.34 4.26 2.61 6.74 3.97 2.83 6.23 3.74 3.12
27°C
8.25 5.32 2.05 7.96 5.20 2.22 7.66 5.08 2.40 7.35 4.96 2.61 6.75 4.64 2.83 6.24 4.39 3.12
630
19°C
30°C
8.29 6.56 2.05 8.00 6.42 2.22 7.72 6.27 2.41 7.42 6.12 2.61 6.83 5.72 2.83 6.34 5.41 3.13
33°C
8.43 8.43 2.06 8.17 8.17 2.23 7.91 7.91 2.42 7.65 7.65 2.63 7.08 7.08 2.86 6.62 6.62 3.15
27°C
9.05 4.52 2.09 8.73 4.41 2.26 8.41 4.30 2.45 8.07 4.18 2.66 7.42 3.90 2.88 6.86 3.68 3.18
30°C
9.06 5.54 2.09 8.74 5.43 2.26 8.42 5.31 2.45 8.08 5.19 2.66 7.43 4.86 2.88 6.87 4.61 3.18
22°C
33°C
9.08 6.50 2.09 8.76 6.37 2.26 8.44 6.24 2.45 8.11 6.11 2.66 7.46 5.73 2.89 6.91 5.44 3.18
36°C
9.13 7.35 2.09 8.84 7.21 2.27 8.53 7.06 2.46 8.22 6.89 2.67 7.58 6.45 2.90 7.07 6.08 3.20
21°C
7.75 5.09 2.03 7.47 4.96 2.20 7.18 4.83 2.38 6.88 4.69 2.58 6.31 4.37 2.80 5.82 4.11 3.09
24°C
7.79 6.18 2.04 7.51 6.04 2.20 7.23 5.89 2.38 6.94 5.74 2.59 6.37 5.35 2.80 5.88 5.05 3.09
16°C
27°C
7.92 7.09 2.04 7.66 6.90 2.21 7.40 6.71 2.39 7.14 6.50 2.60 6.59 6.02 2.82 6.14 5.62 3.11
30°C
8.31 8.31 2.06 8.07 8.07 2.23 7.82 7.82 2.42 7.57 7.57 2.63 7.01 7.01 2.85 6.54 6.54 3.15
24°C
8.53 4.88 2.07 8.22 4.76 2.24 7.91 4.64 2.42 7.59 4.51 2.63 6.96 4.21 2.85 6.43 3.97 3.14
27°C
8.56 5.65 2.07 8.25 5.52 2.24 7.94 5.39 2.43 7.62 5.26 2.63 7.00 4.92 2.85 6.47 4.65 3.14
670
19°C
30°C
8.63 6.95 2.07 8.32 6.80 2.24 8.02 6.64 2.43 7.72 6.48 2.64 7.11 6.05 2.86 6.60 5.70 3.16
33°C
8.82 8.82 2.08 8.56 8.56 2.26 8.29 8.29 2.45 8.02 8.02 2.66 7.43 7.43 2.89 6.95 6.95 3.19
27°C
9.36 4.78 2.11 9.03 4.67 2.28 8.69 4.55 2.47 8.34 4.43 2.68 7.66 4.14 2.91 7.08 3.91 3.20
30°C
9.38 5.89 2.11 9.05 5.78 2.28 8.71 5.65 2.47 8.36 5.52 2.68 7.68 5.17 2.91 7.10 4.90 3.20
22°C
33°C
9.41 6.90 2.11 9.09 6.78 2.29 8.75 6.64 2.48 8.41 6.49 2.69 7.74 6.08 2.91 7.17 5.77 3.21
36°C
9.50 7.79 2.11 9.20 7.65 2.29 8.88 7.48 2.49 8.56 7.30 2.70 7.91 6.81 2.93 7.38 6.41 3.23
Model: FTYN80FXV1 - RQ71CXY1
Heating Mode
ID DB
-9°C
TC
SC
15°C
4.607
4.607
17°C
4.486
4.486
19°C
4.365
4.365
21°C
4.244
4.244
23°C
4.124
4.124
25°C
4.003
4.003
27°C
3.882
3.882
Remark:
AFR: Air fl ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling / Heating Capacity (kW)
SC: Sensible Cooling / Heating Capacity (kW)
PI: Power Input (kW)
Notes:
1. Ratings shown are net capacities.
2.
shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 19°C to 46°C DB (cooling) / -9°C to 18°C WB (heating) without pressure trip.
37
19°C
25°C
SC
PI
TC
SC
PI
-6°C
-5°C
TC
SC
TC
SC
5.214
5.214
5.416
5.416
5.121
5.121
5.289
5.289
5.029
5.029
5.162
5.162
4.908
4.908
5.035
5.035
4.759
4.759
4.907
4.907
4.609
4.609
4.780
4.780
4.460
4.460
4.653
4.653
Frost Region
Outdoor temperature
30°C
35°C
TC
SC
PI
TC
SC
Outdoor WB
6°C
12°C
TC
SC
TC
7.643
7.643
8.858
7.634
7.634
8.703
7.625
7.625
8.548
7.499
7.499
8.393
7.257
7.257
8.239
7.015
7.015
8.084
6.773
6.773
7.929
40°C
PI
TC
SC
PI
TC
15°C
SC
TC
SC
TC
8.858
9.465
9.465
10.072 10.072
8.703
9.305
9.305
9.908
8.548
9.146
9.146
9.743
8.393
8.986
8.986
9.579
8.239
8.827
8.827
9.414
8.084
8.667
8.667
9.250
7.929
8.507
8.507
9.086
46°C
SC
PI
18°C
SC
9.908
9.743
9.579
9.414
9.250
9.086

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents