FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open when operating unit.
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When
lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never
use tools. If the knob will not push in or turn by hand, don't try
to repair it, call a qualified service technician or gas supplier.
Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Imme-
diately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
INSTRUCTIONS
1. STOP! Read the safety information, column 1.
2. Make sure equipment shutoff valve is fully open.
3. Press in and turn control knob clockwise
4. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B" in the
safety information. If you don't smell gas, go to the next step.
5. Turn control knob counterclockwise
and press in. Keep control knob pressed in for five (5) seconds.
Note: You may be running this log set for the first time after
hooking up to gas supply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will allow air to bleed
from the gas system.
• If control knob does not pop up when released, contact a quali-
fied service person or gas supplier for repairs.
6. With control knob pressed in, push down and release ignitor
button. This will light pilot. Visually locate the pilot on the control
valve cover by the edge of the burner pan to look for flame. If
needed, keep pressing ignitor button until pilot lights.
Note: If the pilot will not stay lit after several tries, turn the gas
control knob to OFF and call your service technician or gas sup-
plier.
10
LIGHTING
to the OFF position.
to the PILOT position
Superiorfireplaces.US.com

OPERATION

7. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
8. Turn control knob counterclockwise
Burner should light. If burner does not light, call a qualified service
person.
9. To leave pilot lit and shut off burners only, turn control knob
clockwise
Ignitor
Figure 15 - Ignitor and Control Knob
Pilot
Burner
Figure 16 - Thermocouple and Pilot
1. Turn control knob clockwise
2. Press in and turn control clockwise
3. Close equipment shutoff valve (see Figure 5, page 7).
During 2-3 hour appliance break-in period, you may detect an odor
from the appliance as various paints and compounds used in manu-
facturing of this log set cure. This is a normal and temporary situation
that is not cause for alarm. However, you may want to provide extra
ventilation to the room during this time.
To ensure proper curing of logs:
• Ignite a 2" flame and maintain it for 1 hour.
• Burn logs in consecutive 1 hour periods raising flame an additional
2" to full flame height for a total of three hours.
to the ON position.
to the PILOT position.
Control Knob Pilot
ON
OFF
FROM "PILOT" POSITION
SLIGHT PUSH TO
On
TURN OFF
PULL PUSH
Thermocouple
TO TURN OFF GAS
TO APPLIANCE
to the PILOT position.
to the OFF position.
CURING
LOGS
Off
126900-01_B