9. Snap the AP-6511 on to the mounted wall plate and secure the AP-6511 using the mounting
plate lock screw. This connection does not require the use of tools or fastening hardware.
Once installed, no cables extend from the AP-6511 since they are hidden from view within
the Telco Box.
10. Cable the Access Point using a Power Injector solution (Part No. AP-PSBIAS-1P2-AFR) as
described in the following substeps:
a. Connect an RJ-45 CAT5 Ethernet cable between the network data supply (host) and the
Power Injector's Data In connector.
b. Connect an RJ-45 CAT5 Ethernet cable between the Power Injector's Data & Power Out
connector and the AP-6511 Access Point.
c. Ensure the cable length from the Ethernet source (host) to the Power Injector and Access
Point does not exceed 100 meters (333 ft). The Power Injector has no On/Off power
switch. The Power Injector receives power as soon as AC power is applied. For more
information, see "
11. Verify the behavior of the AP-6511 Access Point LEDs. For more information, see "
Indicators
" on page 14.
12. The AP-6511 is ready to configure. For information on basic Access Point device
configuration, see "
Power Injector System
Defining a Basic AP-6511 Configuration
" on page 5.
" on page 15.