11 • Maintenance
Maintaining the Moistener
Cleaning the Shield and Wick (cont'd)
3.
Pull up and remove the shield and wick from the moistener tank
4.
Separate wick from the shield. Clean the wick in plain water,
and rinse thoroughly. Blot the excess water from the wick.
i
NOTE:
thoroughly.
5.
Place the wick back into the shield.
6.
Push the wick and shield back into moistener tank. Be sure that
the underside of the shield is in contact with the top of the wick.
Press firmly on both ends of the shield to make sure it snaps
into place.
7.
Slide the tank back in place.
8.
Replace the stripper blade/brush assembly by sliding it back on
its track until it snaps into position.
9.
Fill the moistener bottle, place it in the feeder, and close the
access cover. Check the indicator in the top cover to see that it
is all blue.
11-14
Replace the wick and shield if they cannot be cleaned
Shield
Wick