General
Dimensions
Cabinet
Sample Pump
Vertical Lift
Sample Transport Velocity
Pump Flow Rate
Liquid Sensor
Sample Volume
Sample Volume Repeatability
Sample Volume Capacity
Sampling Modes
Interval Between Samples
Multiplex
Intake Purge
Pump/Controller Housing
User Interface
Internal Clock
Programming Features
Diagnostics
Program Delay
Program Language
Manual Sample
Intake Rinse
Intake Fault
8837spc.fm
Specifications are subject to change without notice.
Width: 71 cm (28 in.)
Depth: 71 cm (28 in.)
Height: 125 cm (49 in.)
Weight: 79 kg (175 lb)
Fiberglass reinforced plastic with beige UV-inhibited polymer laminate
High speed peristaltic, dual roller, used with custom purchased
Dow Corning Silastic Rx50 medical grade silicone rubber pump tube
27 ft maximum (Remote Pump Option recommended for lifts from 22 to 35 ft)
2 ft/sec. minimum, at 15 ft vertical lift in a
60 mL/sec at 3 ft vertical lift in a
Single sensor, non-contact, ultrasonic
Programmed in milliters, in one mL increments from 10 to 9,999 mL
±5% typical
(24) 1 liter polyethylene and/or 350 mL glass bottles
(8) 2.3 liter polyethylene and/or 1.9 liter glass bottles
(4) 3 gallon polyethylene and/or 2½ gallon glass bottles
(2) 3 gallon polyethylene and/or 2½ gallon glass bottles
(1) 6 gallon polyethylene composite container, or 3 gallon poly, or 2.5 gallon glass
Multiple Bottle Time, Multiple Bottle Flow, Composite Time, Composite Flow, Flow with
Time Override, Variable Interval, Start/Stop, and Level Actuation
Selectable in single increments from 1 to 9,999 flow pulses (momentary contact
closure 25 msec. or 5–12 V dc pulses; 4–20 mA interface optional), or 1 to 9,999
minutes in one minute increments
Multiple Bottle Mode: Programming allows multiple samples per bottle and/or multiple
bottles per sample collection.
Air purged automatically before and after each sample; duration automatically
compensated for varying intake lengths
NEMA 4X, 6. High impact injection molded ABS; submersible, watertight, dust tight,
corrosion and ice resistant
18 key membrane switch keypad; 24 character alphanumeric liquid crystal display
Indicates real time and date; 0.007% time base accuracy
Tests RAM, ROM, pump, and distributor
Sampler start at time day, or delay in minutes is user programmable
English, French, German, Italian, Spanish, Swedish, Czech, Danish, and Dutch
Initiates a sample collection independent of program in progress
Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3
rinses.
Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained
on initial attempt.

Specifications

3
/
in ID intake tube
8
3
/
in. ID intake line
8
3
5
/
in. ID by
/
in. OD
8
8
Page 9