Intel H2000 Technical Product Specification page 61

Server chassis
Hide thumbs Also See for H2000:
Table of Contents

Advertisement

Front Panel Control and Indicators
Color
State
Green
Blink
Degraded
Amber
Blink
Non-critical
Amber
Solid on
Critical, non-
recoverable
Notes:
1.
The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to
provide the contribution to the system status LED.
2.
Blink rate is ~ 1Hz at 50% duty cycle.
Revision 1.5
Criticality
BIOS detected
1.
Unable to use all of the installed memory (more than one DIMM
installed).
2.
In a mirrored configuration, when memory mirroring takes place
and system loses memory redundancy. This is not covered by
1
(2).
3.
PCI Express* correctable link errors.
4.
Integrated BMC detected
5.
One of redundant power supplies not present.
6.
CPU disabled – if there are two CPUs and one CPU is disabled.
7.
Fan alarm – Fan failure. Number of operational fans should be
more than minimum number needed to cool the system.
8.
Non-critical threshold crossed – Temperature, voltage, power
nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors.
9.
Battery failure.
10. Predictive failure when the system has redundant power
supplies.
Non-fatal alarm – system is likely to fail
BIOS Detected
1.
In non-mirroring mode, if the threshold of ten correctable errors
is crossed within the window.
2.
PCI Express* uncorrectable link errors.
Integrated BMC Detected
1.
Critical threshold crossed – Voltage, temperature, power nozzle,
power gauge, and PROCHOT (Therm Ctrl) sensors.
2.
VRD Hot asserted.
3.
One of the redundant power supplies failed.
4.
Minimum number of fans to cool the system are not present or
have failed.
Fatal alarm – system has failed or shutdown
BIOS Detected
1.
DIMM failure when there is one DIMM present and no good
memory is present.
2.
Run-time memory uncorrectable error in non-redundant mode.
3.
CPU configuration error (for instance, processor stepping
mismatch).
Integrated BMC Detected
11. CPU CATERR signal asserted.
12. CPU 1 is missing.
13. CPU THERMTRIP.
14. System cooling fan failure.
15. No power good – redundant power fault.
Power Unit Redundancy sensor – Insufficient resources
offset (indicates not enough power supplies are present).
Intel order number: G59059-006
®
Intel
Server Chassis H2000 Family TPS
Description
1
1
1
1
51