4. Adjustment

4-1 Before adjusting
4-1-1 Selection of adjustment
When any parts in the table 4-1 are changed, choose
the proper adjusting items with the chart.
4-1-2 Setting of condition before adjustment
1. Before starting adjustment, warm up the projector
for about 10 minutes.(Blank white)
2. Set Zoom Wide to Max. And project an image
with more than 1m (40 inches) in diagonal size.
3. Shift the Lens to the highest position with the
[LENS SHIFT +] button.
4. Normalizing the video adjustment.
(Press the [MENU] button of the Remote control
transmitter to display the MAIN menu. After
pressing the [ ] key, use the [ ] or [ ] key to
select [RESET]. Reset menu will appear by the [ ]
key, then choose [EXECUTE]. Next, open the
PICTURE1 menu. Choose RESET and perfom
EXECUTE by the same operation described above.
Table 4-1: Relation between the replaced part and adjustment
Replaced
Ghost
Flicker
part
(Chap.4-2)
(Chap.4-3)
Dichroic
optics unit
LCD/LENS
prism
assembly
PWB
assembly
Drive
Lamp
unit
assembly
PWB
assembly
Dust sensor
: means need for adjustment.
: means recommended.
*note :The MAIN and PICTURE1 menu is not
reset with no signal.
5. Set the NORMAL at GAMMA in the PICTURE1 menu.
6. Perform all adjustments from the FACTORY MENU.
Perform the following operations to display the
FACTORY MENU.
a. Press the [MENU] button on the Remote control
transmitter (the MAIN menu will appear).
b. Select the [RESET] in the MAIN menu, and
then press the [ ] button.
c. Next, press the [RESET] button one time. And
hold the [RESET] button for 3 seconds or
more (the FACTORY MENU will appear).
5
Adjustment
White
Color
NRSH
balance
uniformity
(Chap.4-4)
(Chap.4-5)
(Chap.4-6)
: means not need for djustment.
AIR
FILTER
(Chap.4-7)

Advertisement