6-10 Regarding the indicator lamps

• When the interior portion has become overheated, for safety purposes, the power source may be automati-
cally turned off, and the indicator lamps may also be turned off. In such a case, press the "○" (OFF) side of
the power switch, and wait at least 45 minutes. After the unit has suffi ciently cooled down, please make confi r-
mation of the attachment state of the lamp and lamp cover, and then turn the power on again.
Lighting and fl ashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings
as described in the Table below. Please respond in accordance with the instructions within the Table.
POWER
LAMP
indicator
indicator
indicator
Lighting in
Turned
orange
off
Blinking in
Turned
green
off
Lighting in
Turned
green
off
Blinking in
Turned
orange
off
Blinking in
-
red
Lighting or
Lighting
blinking in
in red
red
Lighting or
Blinking
blinking in
in red
red
Lighting or
Turned
Blinking
blanking
off
in red
Lighting or
Turned
Lighting
blinking in
off
red
Lighting in
Alternative blinking
green
in the red
Lighting in
Simultaneous
green
blinking in red
TEMP
Turned
The projector is in a standby state.
off
Turned
The projector is warming up. Please wait.
off
Turned
The projector is in an ON state. Ordinary operations may be performed.
off
Turned
The projector is cooling down. Please wait.
off
The projector is cooling down. A certain error has been detected.
-
Please wait until the STANDBY/ON indicator fi nishes blink, and then perform the proper
response measure using the item descriptions below as reference.
The lamp does not light, and there is a possibility that interior portion has become heated.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has suffi ciently cooled down, please make confi rmation of the following items,
and then turn the power on again.
Turned
• Is there blockage of the air passage aperture?
off
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment, please change the lamp by referring
to the section "Lamp".
Either there is no lamp and/or lamp cover, or either of these has not been properly fi xed.
Turned
Please turn the power off, and allow the unit to cool down at least 45 minutes. After the
off
projector has suffi ciently cooled down, please make confi rmation of the attachment state
of the lamp and lamp cover, and then turn the power on again.
The cooling fan is not operating.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
in red
projector has suffi ciently cooled down, please make confi rmation that no foreign matter
has become caught in the fan, etc., and then turn the power on again.
There is a possibility that the interior portion has become heated.
Please turn the power off, and allow the unit to cool down at least 20 minutes. After the
projector has suffi ciently cooled down, please make confi rmation of the following items,
and then turn the power on again.
in red
• Is there blockage of the air passage aperture?
• Is the air fi lter dirty?
• Does the peripheral temperature exceed 35°C?
There is a possibility that the interior portion has become overcooled. Please use the unit
within the usage temperature parameters (0°C to 35°C). After the treatment, resent the
power to ON.
It is time to clean the air fi lter, or there is no Filter cover. Please immediately turn the
power OFF, and clean or change the air fi lter by referring to the "Air Filter" section of this
manual. After you have cleaned or changed the lamp, please be sure to reset the fi lter
timer. After the treatment, reset the power to ON.