Transmission Protocols; Technical Data; Mechanical Data - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Readers
5.1 RF620R reader
5.1.4.1

Transmission protocols

RS 422 communication
Transmission rates
Start bits
Data bits
Parity
Stop bits
5.1.5

Technical data

5.1.5.1

Mechanical data

Mechanical data
Weight
Dimensions (L x W x H) in mm
Material for housing top section
Material for housing bottom section
Color of housing top section
Color of housing bottom section
Status displays on the device
Interfaces
RS422
Software
Technical and electrical characteristics
Supply voltage
● Permitted range
Supply voltage
20 V input voltage on the reader, typical
24 V input voltage on the reader, typical
30 V input voltage on the reader, typical
Supply voltage
94
3964R protocol
19.2 kbps
57.6 kbps
115.2 kbps
1
8
Odd
1
1850 g
252 X 193 x 52 mm, without connections
ABS (GF 20), silicone-free
Aluminum, silicone-free
Pastel turquoise
Silver
1 LED
Colors: Red, yellow, green
1 x plug (8-pin M12)
SIMATIC S7
21.6 to 30 V DC
Current consumption
(in standby mode, no
transmit power)
135 mA
115 mA
95 mA
Current consumption
(at 500 mW ERP)
System Manual, 06/2010, J31069-D0171-U001-A10-7618
Draft Version 02.06.2010
1
Power consumption (in
standby mode, no transmit
power)
2.7 W
2.76 W
2.85 W
Power requirement
(at 500 mW ERP)
SIMATIC RF600