Minimum Distance To Antenna In Accordance With Etsi - Siemens SIMATIC RF600 System Manual

Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Safety Information
2.3 Safety distance to transmitter antenna
2.3.2

Minimum distance to antenna in accordance with ETSI

Minimum distance to antenna in accordance with ETSI (EU, EFTA, Turkey)
At a transmission frequency of 900 MHz, the wavelength of the electromagnetic wave λ is
approximately 0.34 m. For distances less than 1 λ in the near field, the electrical field strength
diminishes exponentially to the power three over distance, and for distances greater than 1 λ,
it diminishes exponentially to the power two over distance.
The horizontal line at 41.25V/m marks the "safety limit value".
For the maximum permisisble transmission power in accordance with ETSI (2W ERP), the
"safety distance" d = 0.24 m. This means that personnel should not remain closer than 24cm
to the transmitter antenna for extended periods (more than several hours without interruption).
Remaining within the vicinity of the antenna for a brief period, even for repeated periods (at a
distance < 0.24 m), is harmless according to current knowledge.
Distance to transmitter antenna [m] Feld strength [V/m]
If the transmitter power is set lower than the highest permissible value (2 watts ERP), the
"safety distance" reduces correspondingly.
The values for this are as follows:
Radiated power ERP [W]
18
1
5
2,0
1,0
0,5
Draft Version 02.06.2010
% of limit value
10
2
Safety distance to transmitter antenna [m]
0,24
0,17
0,12
System Manual, 06/2010, J31069-D0171-U001-A10-7618
24
5
SIMATIC RF600

Advertisement

Table of Contents
loading