WARNING
Follow the Pressure Relief Procedure Warning on
page 12 to reduce the risk of a fluid injection injury,
moving parts,
or
electric shock.
splashing
in
the eyes or on the skin, injury from
1. Disconnect the hose (47).
2. Loosen the filter bracket
nut
(28). Remove the fluid
filter.
3. Remove the pressure control cover (36). Disconnect
the four motor leads.
4. Unscrew the connector (54). Pull the wires out of the
pressure control.
5.
Remove the pressure control mounting screws
(37).
Remove the pressure control.
Remove
the back plate
(1
6 ) .
6. Install the new pressure control.
1. Remove the back pressure control piate (16).
2. Remove the pressure control cover. Disconnect the
3. Loosen the strain relief bushing (E). Remove the
4. Install the new cord.
power supply cord leads.
power supply cord (43a).
Fig 14-2
BACKVIEW OF PRESSURE CONTROL