Enabling/Disabling Remote Control Wireless Transmission; Loop Out Setting; Id Number Setting; Video Wall Setting - Pioneer PDP-42MVE1 Operating Instructions Manual

Pioneer operating instructions plasma-display pdp-42mve1
Hide thumbs Also See for PDP-42MVE1:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Enabling/disabling remote control wireless
transmission
This function enables/disables remote control wireless
transmission.
Example: Setting "OFF"
Set "ADVANCED OSD" to "ON" in the main menu (1/
2), then perform the following operations.
On "IR REMOTE" of "OPTION3" menu, select "OFF", then
press the MENU/SET button.
PREVIOUS PAGE
TIMER
PWR. ON MODE
KEY LOCK
IR REMOTE
LOOP OUT
ID NUMBER
VIDEO WALL
SEL.
Information
IR REMOTE settings
ON: Enables remote control wireless transmission.
OFF: Disables remote control wireless transmission.
Set "OFF" to avoid unwanted control from other remote
controls.

Loop Out setting

When this feature is set to ON, the received signal will be
looped out.
Example: Setting "ON"
Set "ADVANCED OSD" to "ON" in the main menu (1/
2), then perform the following operations.
On "LOOP OUT" of "OPTION3" menu, select "ON".
PREVIOUS PAGE
TIMER
PWR. ON MODE
KEY LOCK
IR REMOTE
LOOP OUT
ID NUMBER
VIDEO WALL
SEL.
Information
LOOP OUT settings
ON: The received signal will be looped out via PC1
terminal or VIDEO1 terminal.
OFF: The received signal will not loop out.
* Even if LOOP OUT is ON, signals won't be sent out if
POWER is being turned off.
To connect another display...
See page 3.
If the PC1 signal is present at the time the
power switched on...
The PC1 input will be displayed regardless of the setting
of LOOP OUT.
24
En
OPTION3
3 / 3
:
LAST
:
OFF
:
OFF
:
OFF
:
ALL
EXIT RETURN
ADJ.
OPTION3
3 / 3
:
LAST
:
OFF
:
ON
:
ON
:
ALL
ADJ.
EXIT RETURN

ID number setting

When using more than one of these displays, this function
sets ID numbers so that operation of the remote control
does not cause multiple monitors to operate at the same
time.
Example: Setting "2"
Set "ADVANCED OSD" to "ON" in the main menu (1/
2), then perform the following operations.
On "ID NUMBER" of "OPTION3" menu, select "2".
OPTION3
PREVIOUS PAGE
TIMER
PWR. ON MODE
KEY LOCK
IR REMOTE
LOOP OUT
ID NUMBER
VIDEO WALL
SEL.
ADJ.
* To reset back to ALL
Press the CLEAR button.
Information
ID NUMBER settings
ALL: ID NUMBER will not be set.
1 to 256: ID NUMBER will be set.
When the ID NUMBER have been set
You can also set ID NUMBER for each remote control
to operate the plasma display individually. To do so,
see below.
To set the ID number for the remote control
Example: Setting "2"
Press the ID NO. SET button on the remote control.
The "ID NO. SET" screen appears.
On "ID NUMBER" of "ID NO. SET" menu, select "2".
ID NO.SET
POSITION :
ID NUMBER
ADJ.
* To reset back to ALL
Press the CLEAR button.

Video Wall setting

Use this feature to configure a 4-25 video wall.
Set "ADVANCED OSD" to "ON" in the main menu (1/
2), then perform the following operations.
On "OPTION3" menu, select "VIDEO WALL", then press
the MENU/SET button.
The "VIDEO WALL" screen appears.
VIDEO WALL
DIVIDER
POSITION
DISP. MODE
AUTO ID
SCREEN
P. ON DELAY
ABL LINK
REPEAT TIMER
SEL.
ADJ.
Note: A contingency method of shutting off the electric
power should be used in cases of emergency during video
wall setup.
3 / 3
:
LAST
:
OFF
:
ON
:
OFF
:
2
EXIT RETURN
1
:
2
EXIT RETURN
:
1
:
NORMAL
:
OFF
:
OFF
:
OFF
:
OFF
EXIT RETURN

Advertisement

Table of Contents
loading

Table of Contents