EXCELL PRECISION CO., LTD.
RS232 DATA FORMAT
When F2 setting is "1" or "2"
(1) Weight unit is g.
1
2
3
4
5
,
HEAD
HEAD
(2) Weight unit is kg/lb
1
2
3
4
5
,
HEAD
HEAD
(3) Weight unit is g, lb or oz.
1
2
3
4
5
6
HEAD
,
HEAD
(4) Weight unit is Catty.
1
2
3
4
5
HEAD
,
HEAD
HEAD1 ( 2 BYTES )
OL -
Overload , Under load
ST -
Display is Stable
US -
Display is Unstable
DATA ( 7 or 8 BYTE )
2D ( HEX ) = " – " ( MINUS )
2B ( HEX ) = " + " (PLUS)
2E ( HEX ) = " . " ( DECIMAL POINT )
UNIT ( 2、3 or 4 BYTE )
kg
= 6B ( HEX ) ; 67 ( HEX )
lb
= 6C ( HEX ) ; 62 ( HEX )
tl.T
= 74 ( HEX ) ; 6C ( HEX ) ; 2E ( HEX ) ; 54 ( HEX )
hkg
= 68 ( HEX ) ; 6B ( HEX ) ; 67 ( HEX )
01008044
6
7
8
9
10 11 12 13 14 15 16 17
,
±
6
7
8
9
10 11 12 13 14 15 16 17 18
,
±
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21
±
,
DATA
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20
±
,
HEAD2 ( 2 BYTES )
NT -
GS -
DATA
UNIT CR
DATA
DATA
NET Mode
GROSS Mode
14
g
LF
kg/lb
UNIT
CR
LF
twg
UNIT
CR
LF
Catty
UNIT
CR LF
ZSME100000117