Cord Sets and Receptacles
Use only high quality, well-insulated, grounded
extension cords with the generator's receptacles.
Inspect extension cords before each use.
Check the ratings of all extension cords before you use
them. Check the operator's manuals of devices for the
manufacturer's recommendations.
WARNING Damaged or overloaded electrical
cords could overheat, arc, and burn
resulting in death or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
12
120 Volt AC, 20 Amp, Duplex Receptacle
The duplex receptacle are protected against overload
by a push to reset circuit breaker.
Use receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 1,500 watts
(1.5 kW) at 12.5 Amps of current. Use cord sets
that are rated for 125 Volt AC loads at 15 Amps (or
greater).
NOTICE Receptacles may be marked with rating
value greater than generator output capacity.
• NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
• DO NOT overload the generator. See Don't Overload
Generator.