ProCurve 8200zl Series Management And Configuration Manual page 447

Table of Contents

Advertisement

ProCurve(config)# redundancy management-module
All configuration files and software images on the off-line management
module will be overwritten with the data from the current active
management module. Do you want to continue [y/n]?
ProCurve(config)#
ProCurve(config)# show redundancy
Settings
--------
Mgmt Redundancy : enabled
Statistics
----------
Failovers
Last Failover :
Slot Module Description
---- ---------------------------------------- -------- ----------- ---------
1
ProCurve J9092A Management Module 8200zl Standby
2
ProCurve J9092A Management Module 8200zl Active
1
ProCurve J9093A F2 Fabric Module 8200zl
2
ProCurve J9093A F2 Fabric Module 8200zl
Figure 15-2. Example of Enabling Redundancy
N o t e
: 0
The no version of the redundancy management-module command is used to
disable redundancy on the switch, as seen in Figure 15-3. The show redundancy
command displays "Mgmt Redundancy" as disabled. The standby
management module in slot 1 is now offline. The management module in slot
2 remains the active management module.
ProCurve recommends that you leave redundancy enabled. If the active
management module has a hardware failure, the standby module may take
over and may have an old configuration since file synchronization has not
occurred.
The redundancy management-module command allows you to shut down a
management module that is not functioning correctly without physically
removing the module. However, removing the management module is the
recommended method.
y
Redundancy enabled
Status
Enabled
Enabled
Redundancy (Switch 8212zl)
Using Redundant Management
SW Version
Boot Image
K.12.XX
Primary
K.12.XX
Primary
15-7