Time Sync Method [None] : SNTP
SNTP Mode [Disabled] : Unicast
Poll Interval (sec) [720] : 720
Tftp-enable [Yes] : Yes
Time Zone [0] : 0
Daylight Time Rule [None] : None
Note: The Menu interface lists only the highest priority SNTP server, even if others are configured. To view all SNTP servers configured
on the switch, use the CLI show management command. Refer to "SNTP Unicast Time Polling with Multiple SNTP Servers" on page
9-25.
Figure 9-3. SNTP Configuration Fields for SNTP Configured with Unicast Mode
Note: This step replaces any previously configured server IP
address. If you will be using backup SNTP servers (requires use
of the CLI), then refer to "SNTP Unicast Time Polling with
Multiple SNTP Servers" on page 9-25.
[v]
iii. Press
to move the cursor to the Server Version field. Enter the
value that matches the SNTP server version running on the device
you specified in the preceding step (step ii). If you are unsure
which version to use, ProCurve recommends leaving this value
at the default setting of 3 and testing SNTP operation to determine
whether any change is necessary.
Note: Using the menu to enter the IP address for an SNTP server
when the switch already has one or more SNTP servers config-
ured causes the switch to delete the primary SNTP server from
the server list and to select a new primary SNTP server from the
IP address(es) in the updated list. For more on this topic, refer to
"SNTP Unicast Time Polling with Multiple SNTP Servers" on page
9-25.
[>]
to move the cursor to the Poll Interval field, then go to
iv. Press
step 6.
6.
In the Poll Interval field, enter the time in seconds that you want for a Poll
Interval. (For Poll Interval operation, see table 9-1, "SNTP Parameters",
on page 9-5.)
Press [Enter] to return to the Actions line, then [S] (for Save) to enter the
7.
new time protocol configuration in both the startup-config and running-
config files.
SNTP: Viewing, Selecting, and Configuring
Server Address : 10.28.227.15
Server Version [3] : 3
Time Protocols
9-7