1-23. PEAK CUT OPERATION

The Current Value is limited to reduce the power consumption by External Input.
During the PEAK CUT OPERATION,
"CURRENT OVERLOAD OPERATION", "ECONOMY OPERATION" and "LOW NOISE OPERATION"
are effective, and the outdoor unit operates by lowest current of them.
However, this function becomes invalid during DEFROST OPERATION.
(Table 22 : Outline of Peak Cut Operation )
PEAK CUT LEVEL
Peak Cut
For Rated Capacity
*Percentage is rated electrical power ratio.
1-24. HUMAN SENSOR (OPTION )
Auto saving operation
If no one enters the room during the set time (15, 30, 60, 90, 120, 180 minutes), the set
temperature will be automatically controlled.
(When someone comes back into the room, the human sensor will detect this, and automatically
revert to the original settings).
(Table 10)
Operation mode
Cool / Dry
Heat
Auto off operation
If no one enters the room during the set time (1 to 24 hours in 1 hour increments), the air
conditioner will automatically stop operation.
Application range
LEVEL 1
Forced
thermostat-OFF
Operation details
(if there is no one in the room for a while)
The set temperature will be increased by
a maximum of approximately 2
The set temperature will be decreased by
a maximum of approximately 2
LEVEL 2
LEVEL 3
50%
75%
* High limit : 30
°C.
* Low limit : 16
°C.
Equal sensitivity
range of temperature
01-28
LEVEL 4
100%
°C
°C
Ceiling height :
3.2m
Detecting position :
0.8m from floor surface