Low Noise Operation - Fujitsu AUXG45LRLB Service Instruction

Cassette type inverter
Hide thumbs Also See for AUXG45LRLB:
Table of Contents

Advertisement

1-22. LOW NOISE OPERATION

The compressor speed and the outdoor unit fan sp
by External Input.
During the LOW NOISE OPERATION,
"CURRENT OVERLOAD OPERATION", "ECONOMY OPERATION" and "PEAK CUT OPERATION"
are effective, and the outdoor unit operates by lowest current of them.
However, during the DEFROST OPERATION, the compressor operates by the speed
for DEFROST OPERATION.
( Table 20 : Detail of Low Noise Operation )
Low Noise mode
Cooling
LEVEL 1
Heating
Cooling
LEVEL 2
Heating
*The performance drops when operating in the
Capacity priority mode
(1) Operation condition
The function setting is set the "1" for the capacity priority mode.
(2) Check the capacity condition
Shortage
Required compressor speed > Limited compressor speed of low noise mode
Required compressor speed < Limited compressor speed of low noise mode
Enough
(3) Operation
When detect the shortage capacity or enough capacity condition continuous 30 minute,
the mode is upped or downed for 1 step.
Automatic switching 1
Level 1 setting
30min
Shortage
Low noise
mode 1
30min
Enough
Outdoor fan speed
(Upper / Lower)
[rpm]
540/520
570/550
540/520
570/550
LOW NOISE OPERATION
Automatic switching 2
Level 2 setting
Low noise
Normal
mode 2
operation
01-27
eed are limited to reduce the operation noise
Compressor speed
[rps]
Model 45
Model 54
68
75
75
85
54
58
62
68
.
30min
Shortage
Low noise
mode 1
30min
Enough
30min
Shortage
Normal
operation
30min
Enough