1-14. AUTO RESTART

When the power was interrupted by a power failure, etc. during operation, the operation contents
at that time are memorized and when power is recovered, operation is automatically resumed with
the memorized operation contents.
When the power is interrupted and recovered during timer operation, timer operation is canceled,
but only setting time is memorized.
[Operation contents memorized when the power is interrupted]
Operation mode
Set temperature
Set air flow
Timer mode and timer time (Set by wireless remote controller)
10°C HEAT (Wireless remote controller is in use)
ECONOMY
Air flow direction (Swing setting)
Individual air flow direction (Swing setting)
Human sensor auto saving (setting/timer)
Human sensor auto off (setting/timer)
Energy saving setting
Each central setting
1-15. PUMP DOWN For Model 30,36