Operation; Preparing For Start-Up; Starting Up The Product; Switching On The Product - Vaillant MAG HK 13-2/0-3 H Operating Instructions Manual

Turbom mag pro gas-fired in stantaneous water heater
Table of Contents

Advertisement

Conditions : 13 L products
The water flow can assume various values: 6, 7, 8, 9,
10 L/min.
Conditions : 17 L products
The water flow can assume various values: 6, 7, 8, 9, 10, 11,
12, 13, 14 L/min.
The value that was last set for the water flow is saved and
reapplied when ECO mode is activated.
3.6.3
Bath-filling mode
In bath-filling mode, you can specify the water volume that
you require (e.g. 160 L).
You can only select the bath-filling mode on the main remote
control for the product.
Note
When the water volume is 10 L below the set wa-
ter volume, an audible signal sounds. The display
shows the current water volume. Once the set wa-
ter volume is reached , an audible signal sounds
rapidly , to notify user to close the water tap . If the
water tap is not closed, the display shows the cur-
rent water volume.
The product sounds an audible signal if the bath
has not yet been filled after 42 minutes.
4

Operation

Warning.
Risk of being scalded by hot water.
Incorrectly set water temperatures and hot
water in the lines can lead to scalding.
Check the water temperature with your
hand.
4.1

Preparing for start-up

1
2
1.
Open the cold water stop valve (3).
2.
Open the hot water stop valve (1).
3.
Open the water tap to check the water flow.
4.
Close the water tap.
5.
Switch on the power supply to the product.
6.
Open the gas isolator cock (2).
0020208984_00 turboMAG pro Operating instructions
4.2
4.3
1.
2.
4.4
4.5
1.
2.
3.
4.6
1.
2.
3.
4.
5.
3

Starting up the product

Only start up the product once the casing has been com-
pletely closed.

Switching on the product

Press
.
The display shows the preset temperature in the
normal operating mode (default setting: 42 ° C ).
Once the self-test is complete , the display goes off
and the product goes into standby mode.
Open the water tap.
The product starts up automatically. If ignition prob-
lems occur, open and close the water tap several
times ( Please ensure there is a momentary pause in
between each water tap opening and closing ) .

Selecting operating modes

Press
to choose between normal operating mode,
m
ECO mode and bath-filling mode.
The backlighting lights up.
Note
You can only change the operating mode
when there is no existing hot water request.

Setting the normal operating mode

m
Press
.
Press
or
in order to set the water temperature.
The display shows the set temperature for
three seconds.
Open the water tap.
The display shows the current water temperature.

Setting ECO mode

To switch from normal operating mode to ECO mode
while in standby, press
m
The preset water flow flashes in the display.
Press
or
to select one of the values for the
water flow.
Wait 3 seconds without applying any settings.
The current set water temperature flashes in the
display.
Press
or
to set the water temperature.
Open the water tap.
The display will show the current water temperature
after 3 seconds.
Operation 4
once.
7