Power-Up Failure - Motorola ASTRO XTS 5000 Detailed Service Manual

Vhf uhf range 1 uhf range 2 700 - 800 mhz
Hide thumbs Also See for ASTRO XTS 5000:
Table of Contents

Advertisement

Troubleshooting Charts: Power-Up Failure
5.3
Power-Up Failure—Page 1
Isolate and
Repair Problem
See DC Supply
Failure flowchart
Replace U301
(Flipper) and
place R528
back on board
Signal may appear
for a very short period
of time (50 ms). Use
an oscilloscope with
trigger to capture signal.
6881094C31-E
Radio
Power-Up
Failure
Verify Standard
Bias in
Table 5-1
Standard
No
Bias OK?
Yes
Remove
R528 (VOCON)
Yes
Fixed?
No
Place R528
back on board
Probe
32.768 kHz
Clock at R316
No
Signal
Present?
Yes
Is
VOCON Board
No
NNTN4563, NNTN4819,
or NNTN4717
kit?
Yes
Remove
Shield
SH101
Verify integrity
of C308 and
2
C309
1
MAEPF-27389-C
5-3
November 16, 2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents