Standard Connections - Toshiba TOSVERT VF-AS1 Instruction Manual

High performance
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

3. Standard connections

MCCB
Three-phase
main circuit
power supply
[Note 1]
TC
Power supply
Note 1: Connection when using a MCCB with a top coil instead of a MC.
Note 2: A Step-Down transformer is required for 400V/690V models but not for 200V models.
Note 3: As a last resort to prevent fire, be sure to connect a thermal relay (TH-Ry).
Select and connect a thermal relay (TH-Ry) appropriate to the capacity
(Wattage) of the braking resistor.
[Position of terminals]
PA terminal
(M10 screw)
PB terminal
(M10 screw)
PA terminal
PB terminal
* If no power supply is
provided for the control circuit
MC
[Note 2]
Step-Down
transformer
200V
MC
Fuse
PB7-4200K
TH - Ry
[Note 3]
PA
PB
BU+
R/L1
S/L2
T/L3
Inverter
FLB
Surge killer
FLC
FLA
PB7-4400K, -6300K, -6400K
BU+ terminal
(2xM12 screw)
PA terminal
(2xM12 screw)
E6581436
external braking resistor (optional)
Dynamic braking unit
PB7
a case to use the PB unit
BU-
U/T1
V/T2
W/T3
F
Forward run/stop
Reverse run/stop
R
CC
BU- terminal
(2xM12 screw)
PB terminal
(2xM12 screw)
G/E terminal
(2xM12 screw)
Motor
IM

Hide quick links:

Advertisement

Table of Contents
loading