Roland VR-4HD Reference Manual page 27

Hd av mixer
Hide thumbs Also See for VR-4HD:
Table of Contents

Advertisement

{ Undefined (Controller Number 59)
Status
2nd Byte
BnH
3BH
vv: 00H–03H (OFF, PinP, SPLIT, QUAD)
* This transmits the value when the [PinP], [SPLIT], or [QUAD] button has been
operated.
{ Undefined (Controller Number 60)
Status
2nd Byte
BnH
3CH
vv: 00H–01H (OFF, ON)
* This transmits the value when the [OUTPUT FADE] button has been operated.
{ Undefined (Controller Number 61)
Status
2nd Byte
BnH
3DH
vv: 00H–01H (OFF, ON)
* This transmits the value when the [FREEZE] button has been operated.
„System Exclusive Message
Status
Data Byte
F0H
iiH,ddH,...,eeH
F0H:
Status of system exclusive message
ii= ID number:
This is the ID to recognize manufacturer of the exclusive
message (manufacturer ID). The manufacturer ID of Roland is
41H. The ID numbers of 7EH and 7FH are expansion of MIDI
standards and used as universal non-realtime message (7EH) of
universal realtime message (7FH).
dd,...,ee= data:
00H–7FH (0–127)
F7H:
EOX (end of exclusive)
z Data Set 1 (DT1)
This is the message of actual data transmission. Use this when you want to set data
to the unit.
Status
Data Byte
F0H
41H, 10H, 00H, 00H, 00H, 29H, 12H, aaH,
bbH, ccH, ddH, ..., eeH, sum
Byte
Explanation
F0H
Exclusive Status
41H
Manufacturer ID (Roland)
10H
Device ID
00H
1st byte of model ID (VR-4HD)
00H
2nd byte of model ID (VR-4HD)
00H
3rd byte of model ID (VR-4HD)
29H
4th byte of model ID (VR-4HD)
12H
Command ID (DT1)
aaH
Address upper byte
bbH
Address middle byte
ccH
Address lower byte
ddH
Data: actual data to transmit. Multiple byte data is sent in address order.
:
:
eeH
Data
sum
Checksum
F7H
EOX (end of exclusive)
* Data exceeding 256 bytes should be divided into packets of 256 bytes or smaller. If
you send sequentially, the intervals of packets should be longer than 20 ms.
3rd Byte
vvH
3rd Byte
vvH
3rd Byte
vvH
Status
F7H
Status
F7H
MIDI Implementation
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents