Cisco Catalyst 3850 Command Reference Manual page 27

Energywise version 2.8 cisco ios
Hide thumbs Also See for Catalyst 3850:
Table of Contents

Advertisement

EnergyWise Commands
Command Modes
Privileged EXEC
Command History
Release
-
Cisco IOS XE 3E
Cisco IOS 15.0(2)EX1
Usage Guidelines
Use this query with care. It affects the domain member on which you enter the command and other domain
members and endpoints that match the query criteria.
If the timeout value in the energywise query importance privileged EXEC command is too short, the
management station does not receive query results when the domain members and endpoints respond to the
query. For example, if you want to power off a specific phone but the timeout value in the energywise query
importance command is too short, the phone is not powered off. When configuring the timeout, configure a
minimum of 6 seconds to display correct output.
Do not run a query with keywords *. No results are generated.
When sending a WoL magic packet, if you do not know where the device is located, use the energywise
query importance 100 name * wol mac mac-address command to send the packet to all domain members.
Examples
These examples show how to filter with the name:
DomainMember# energywise query importance 50 name phone* collect usage
EnergyWise query, timeout is 6 seconds:
Host Name Usage Level Imp
---- ---- ----- ----- ---
2.2.2.21 phone 0.0 (W) 10 1
2.2.2.21 phone 15.4 (W) 10 1
2.2.2.21 phoneA 0.0 (W) 10 1
2.2.2.22 phone 0.0 (W) 10 1
2.2.2.21 phoneB 0.0 (W) 10 1
2.2.2.22 phoneC 15.4 (W) 10 1
2.2.2.21 phone 0.0 (W) 10 1
2.2.2.23 phoneD 15.4 (W) 10 1
2.2.2.21 phone 0.0 (W) 10 1
Queried: 9 Responded: 9 Time: 0.26 seconds
DomainMember# energywise query importance 80 name * sum usage
EnergyWise query, timeout is 6 seconds:
Total Usage
-----------
346.3 (W)
Queried: 147 Responded: 147 Time: 0.121 seconds
DomainMember# energywise query importance 90 name lobby* collect usage
EnergyWise query, timeout is 6 seconds:
Host Name Usage Level Imp
---- ---- ----- ----- ---
2.2.4.30 lobbyInterface.17 10.0 (W) 10 1
2.2.6.20 lobbypc.17 200.0 (W) 8 90
OL-32343-01
Cisco EnergyWise Cisco IOS Command Reference for Catalyst 3850 Switches, EnergyWise Version 2.8
First EW
Modification
Version
2.6
The default timeout value was changed from 3
seconds to 6 seconds.
2.8
This command was introduced.
2.8
This command was introduced.
energywise query
19

Advertisement

Table of Contents
loading

Table of Contents