Remote Condenser Location - Cornelius IRC630 Installation Manual

I series ice cube machine
Hide thumbs Also See for IRC630:
Table of Contents

Advertisement

NOTE:
a.
Never wire condenser into cuber section. The condenser is an independent electrical con-
nection.
b.
Fan motor will not start until pressure rises to 205 PSIG [14.07 Bars] closing fan cycling
switch.
c.
The condenser fan may cycle off during the harvest cycle - This would be normal.
NOTE:
Installing an Cornelius remote cuber with other than an Cornelius remote condenser
and line set may be reason to void the cuber warranty.
4. Each condenser and cuber is connected with two (2) pre-charged lines.
A.
The pre-charged lines are ordered separately from the condenser to suit each individual application.
B.
The pre-charged line lengths are 20 feet [6.096 meters], 35 feet [10.66 meters] and 55 feet [16.76 me-
ters].
NOTE:
*(Pre-charged is defined as a vapor holding charge - not a portion of the system charge.)
5. Installation of line kits (see drawing) Remove the tubing from the carton. Carefully uncoil the lines so the
tubing doesn't become kinked, and route lines to cuber and condenser.
6. Keep line set as short as possible. Place a 3 foot service loop behind cuber to allow for rear service should
it ever be required.

REMOTE CONDENSER LOCATION

NOTE: Max. line set length for Cornelius cubers is 55 ft. - Do not confuse line
NOTE:
length with calculated line distance.
1. Physical Line Set Length: 55 Ft. Maximum [16.764 meters]
LIQUID
REFRIGERANT
LINE
CORRECT
iii
DISCHARGE
LINE
166240001