Initialization Settings - Sony HDCU1000 Maintenance Manual

Hd camera control unit
Hide thumbs Also See for HDCU1000:
Table of Contents

Advertisement

3-1-4. Initialization Settings

HDCU1000/1080/1500
n
When changing the switch settings from the customer's
setting positions, it is recommended to write down the
customer's setting positions in the following table. After
completing the adjustment, be sure to return the switches
to the customer's setting positions.
Board
Switch
AU-302
S2
S4
AU-303
S3
S5
AVP-6
S500
S501
S600
S601
S602
S603
Set the switches other than the above to the state when shipped from the
factory.
For details of the switch settings, refer to Section 1-7, "On-board Indicator/
Switch/Volume Functions" of the separate Installation Maual.
MM/HDCU1000 Series
Setting
Customer
during
setting
adjustment
PROD
CARBON
PROD
CARBON
0 dB
0 dB
RTS
RTS
RTS
RTS
When using the MSU-900:
. Power supply and signal selector block
ALL button
CAM PW button
TEST1 button
TEST2 button
BARS button
CLOSE button
. Camera/CCU circuit ON/OFF block
DETAIL OFF button
KNEE OFF button
AUTO KNEE button
MATRIX OFF button
. AUTO SETUP block
LEVEL button
WHITE button
BLACK button
. Others
GAMMA OFF button
MASTER GAIN selector button → 0
When using the MSU-950:
. Power supply and signal selector block
ALL button
CAM PW button
TEST button
BARS button
CLOSE button
. AUTO SETUP block
LEVEL button
WHITE button
BLACK button
. Others
*
GAMMA OFF
*
MASTER GAIN
* : Press the function button and select it on the function menu display.
→ OFF (Dark)
→ ON (Lit)
→ OFF (Dark)
→ OFF (Dark)
→ OFF (Dark)
→ ON (Lit)
→ OFF (Lit)
→ ON (Dark)
→ OFF (Dark)
→ OFF (Lit)
→ OFF (Dark)
→ OFF (Dark)
→ OFF (Dark)
→ OFF (Dark)
→ OFF (Dark)
→ ON (Lit)
→ OFF (Dark)
→ OFF (Dark)
→ ON (Lit)
→ OFF (Dark)
→ OFF (Dark)
→ OFF (Dark)
→ ON
(Not highlighted)
→ 0 (0 dB)
3-3 (E)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdcu1080Hdcu1500

Table of Contents