Wiring Switches And Sensors; Dry Contact Inputs, Measurement Option Code 22 (702Dx22); Wireless Output Specifications - Emerson Rosemount 702 Reference Manual

Wireless discrete transmitter
Hide thumbs Also See for Rosemount 702:
Table of Contents

Advertisement

Reference Manual
00809-0200-4702, Rev DA
3.3

Wiring switches and sensors

3.3.1

Dry contact inputs, measurement option code 22 (702DX22)

Figure 3-5. Terminal Diagram
3.3.2

Wireless output specifications

Dual input
The Rosemount 702 Transmitter will accept the input from one or two single pole single throw switches
on inputs S1 and S2. The wireless output of the transmitter will be both a primary variable (PV) and a
secondary variable (SV). The PV is determined by the S1 input. The SV is determined by the S2 input. A
closed switch drives a TRUE output. An open switch drives a FALSE output.
Figure 3-6. Single and Dual Input
Mounting, Wiring Switches, and Sensors: Models 702DX22 and 702DX61
Single input
Mounting, Wiring Switches, and Sensors:
Models 702DX22 and 702DX61
Dual input
S1
CMN
S2
CMN
July 2017
19

Advertisement

Table of Contents
loading

Table of Contents