Ordering Information - Emerson Rosemount 389 Instruction Manual

General purpose ph/orp sensors
Hide thumbs Also See for Rosemount 389:
Table of Contents

Advertisement

Description and specifications
Sensors with SMART preamp (pH only) - II 1 G Ex ia IIC T4 Ga (-20 ºC ≤ Ta ≤ +60 ºC)
Sensors with standard preamp (ORP only) - II 1 G Ex ia IIC T4 Ga (-20 ºC ≤ Ta ≤ +80 ºC) or II 1
G Ex ia IIC T5 Ga (-20 ºC ≤ Ta ≤ +40 ºC)
Per standards EN 60079-0:2012 + A11:2013, EN 60079-11:2012
FM
See online FM Certificate of Compliance for applicable sensor options:
Intrinsically safe for use in Class I, II, and III, Division 1, Groups A, B, C, D, E, F, and G;
Temperature Class T6 Ta = -20 °C to + 60 °C
Intrinsically safe for use in Class I, Zone 0, AEx ia IIC T6 Ta = -20 °C to + 60 °C
Nonincendive for use in Class I, Division 2, Groups A, B, C, and D; Temperature Class T6 Ta
= -20 °C to + 60 °C
Suitable for use in Class II and III, Division 2, Groups E, F, and G; Temperature Class Ta =
-20 °C to + 60 °C Hazardous (Classified) Locations
IS/I, II, III/1/ABCDEFG/T6 Ta = 60 °C - 140332; Entity: I/0/AEX ia IIC/T6 Ta =60 °C - 1400332;
Entity; NI/I/2/ABCD/T6 Ta = 60 °C; S/I, III/2/EFG/T6 Ta = 60 °C; Entity Parameters
Per standards 3600: 1998; 3610: 2010, 3611:2004, 3810:2005
CSA
See online CSA Certificate of Compliance for applicable sensor options:
Intrinsically Safe: Class I, Division 1, Groups ABCD; Class II, Division 1, Groups EFG; Class III,
Class I, Division II, Groups ABCD; Ambient temperature rating -20 °C to + 60 °C; Ex ia IIC; T6
Intrinsically Safe and Non-Incendive: Class I, Division 1, Groups ABCD; Class II, Division 1,
Groups EFG; Class III; Class 1, Division 2, Groups ABCD; Ex ia IIC; T6; Ambient temperature
rating -20 °C to + 60 °C: (Simple Apparatus)
Per standards C22.2 No. 144 -M1987, C22.2 No 157 - M1992, CAN/CSA E60079:0:07,
CAN/CSA E60079:11:02, UL 50, UL 508, UL 913, UL 60079-0:2005, UL 60079-11: 2002
1.4

Ordering Information

The Rosemount 389 and 389VP General Purpose pH/ORP Sensors are housed in a molded
Tefzel body with 1 in. MNPT forward and rear facing threads suitable for insertion,
submersion, or flow through installation. The sensors can be configured with a general
purpose pH, high pH, or platinum ORP electrode. Rosemount 389VP sensors are offered
with SMART preamplifiers for pH measurements and standard integral preamplifiers for
ORP measurements. These sensors may be configured without a preamplifier, but must be
used with a remote preamplifier (j-box or transmitter). Automatic temperature
compensation is standard. Sensors are available with either an integral cable connection
(389) or Variopol (VP6) connector (389VP). Variopol cables sold separately (see
4
Table
5-2).
389/389VP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 389vp

Table of Contents