Suitable for use in Class II and III, Division 2, Groups E, F, and G; Temperature Class Ta = -20
°C to + 60 °C Hazardous (Classified) Locations
IS/I, II, III/1/ABCDEFG/T6 Ta = 60 °C - 140332; Entity: I/0/AEx ia IIC/T6 Ta = 60 °C - 1400332;
Entity; NI/I/2/ABCD/T6 Ta = 60 °C; S/I, III/2/EFG/T6 Ta = 60 °C; Entity Parameters
Per standards 3600: 1998; 3610: 2010, 3611:2004, 3810:2005
CSA
See online CSA Certificate of Compliance for applicable sensor options:
Intrinsically Safe: Class I, Division 1, Groups ABCD; Class II, Division 1, Groups EFG; Class III,
Class I, Division II, Groups ABCD; Ambient temperature rating -20 °C to + 60 °C; Ex ia IIC; T6
Intrinsically Safe and Non-Incendive: Class I, Division 1, Groups ABCD; Class II, Division 1,
Groups EFG; Class III; Class 1, Division 2, Groups ABCD; Ex ia IIC; T6; Ambient temperature
rating -20 °C to + 60 °C: (Simple Apparatus)
Class I, Division 1, Groups ABCD; Class II, Division 1, Groups EFG; Class III; Class I, Division 2,
Groups ABCD; Ex ia IIC; T6; Ambient temperature rating -20 °C to + 60 °C: (Simple
Apparatus)
Per standards C22.2 No. 144 -M1987, C22.2 No 157 - M1992, CAN/CSA E60079:0:07,
CAN/CSA E60079:11:02, UL 50, UL 508, UL 913, UL 60079-0:2005, UL 60079-11: 2002
1.4

Ordering information

The Rosemount 389 and 389VP General Purpose pH/ORP Sensors are housed in a molded
Tefzel body with 1 in. MNPT forward and rear facing threads suitable for insertion,
submersion, or flow through installation. The sensors can be configured with a general
purpose pH, high pH, or platinum ORP electrode. Rosemount 389VP sensors are offered
with SMART preamplifiers for pH measurements and standard integral preamplifiers for
ORP measurements. These sensors may be configured without a preamplifier, but must be
used with a remote preamplifier (j-box or transmitter). Automatic temperature
compensation is standard. Sensors are available with either an integral cable connection
(389) or Variopol (VP6) connector (389VP). Variopol cables sold separately (see
Table 1-3: Rosemount 389 pH/ORP Sensor ordering information
Model
Sensor type
389
pH/ORP Sensor
Preamplifier/cable
01
Integral pramplifier, 25 ft cable
02
No preamplifier, 15 ft cable
Combination electrode
10
pH -GPLR glass
11
pH-high pH glass
12
ORP
8
(1)
Reference Manual
00809-0100-3389
Table
5-2).