Cdi Unit Inspection; Cdi Circuit Inspection - KYMCO Like 50 Service Manual

Table of Contents

Advertisement

15
. ELECTRICAL EQUIPMENT

CDI UNIT INSPECTION

Remove the front cover.
Disconnect the CDI coupler and remove the
CDI unit.

CDI CIRCUIT INSPECTION

Measure the resistance between the
terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
• Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
• Use a Sanwa Electric Tester or Kowa
Electric Tester (TH-5H).
• In this table, "Needle swings then
returns" indicates that there is a charging
current applied to a condenser. The needle
will then remain at "∞" unless the
condenser is discharged.
Use the x KΩ range for the Sanwa Tester.
Use the x 100Ω range for the Kowa Tester.
Probe⊕
Black
(-)Probe
Black
Blue/
15~20KΩ
Yellow
Green
15~20MΩ 600~900Ω
Black/
Yellow
Unit: Ω
Blue/
Black/
Green
Yellow
Yellow
4~7MΩ 4~7MΩ 2~3MΩ
600~900Ω
1000~1500KΩ
4~7MΩ
CDI Unit
Blue/ Yellow
Black/Blue
Violet/ Black
Green
Green/ Black
LIKE 50/125
Violet/Red
Black / Blue
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Like 125

Table of Contents