15
. ELECTRICAL EQUIPMENT

BATTERY REMOVAL

Remove the battery cover.
Disconnect the battery cables .
First disconnect the battery negative (-)
cable and then the positive (+) cable.
Remove the battery.
The installation sequence is the reverse of
removal.
BATTERY CHARGING (OPEN CIRCUIT
VOLTAGE) INSPECTION
Remove the battery cover and disconnect
the battery cables.
Measure the voltage between the battery
terminals.
Fully charged : 13.0V~13.2V
Undercharged
: 12.3V max.
Battery charging inspection must be
performed with an electric tester.
CHARGING METHOD
Connect the charger positive (+) cable to
the battery positive (+) cable.
Connect the charger negative (-) cable to
the battery negative (-) cable.
• Keep flames and sparks away from a
charging battery.
• Turn power ON/OFF at the charger, not
at the battery terminals to prevent sparks
near the battery.
• Charge the battery according to the
current specified on the battery surface
Charging current:Standard: 0.4A
Charging time
: Standard: 5 hours
After charging: Open circuit voltage: 12.8V min.
• Quick charging should only be done in
an emergency.
• During quick charging, the battery
temperature should not exceed 45℃.
• Measure the voltage 30 minutes after
the battery is charged.
Quick
: 4A
Quick
: 0.5 HOUR