2way valve for DHW
N
PCB
T/B
Connecting a 2way valve for DHW
1 . Directly connect a '2way valve for DHW' with 'B7, B8, B9 and B10' in TB-B .
This port can supply power for small-medium sized valve .
Maximum current is 0 . 5 A
NOTE
Specification table
Terminal block (Output)
Connection load
Output (B7~B10)
EHS Control unit_MIM-E03@_IM_E_34413-2.indd 19
2way valve for DHW
L
B7
B8
Initially, the relay is connected between L and B10
Part
Relay
B9
B10
Specification
B7 : Output Power N
B8 : Output Power L
B9 : Output Power L (switched)
B10 : Output Power L (switched)
Direct connect 2way valves (under 0 . 5 A)
AC 230V (MAX 0 . 5 A / 120W)
19